Télécharger Imprimer la page

afriso WAF 04 R-G3/4 Notice Technique page 40

Publicité

Les langues disponibles

Les langues disponibles

8.1.3
Replacing the pressure reducer
1. Dismount the pressure reducer as shown in the following figures.
5
1
3
10
2. Mount the new pressure reducer (reverse sequence of steps). For step
(11), press down the membrane (A) with the finger and re-insert the
ring in the same position it was in when you removed it for dismounting.
3. Adjust the outlet pressure (see chapter "Adjusting the outlet pressure").
All manuals and user guides at all-guides.com
Maintenance
6
2
4
11
A
9
7
8
12
13
14
WAF 04 R
EN
18

Publicité

loading

Produits Connexes pour afriso WAF 04 R-G3/4

Ce manuel est également adapté pour:

Waf 04 r-g1Waf 04 r-g1/4