8.1.3
Replacing the pressure reducer
1. Dismount the pressure reducer as shown in the following figures.
5
1
3
10
2. Mount the new pressure reducer (reverse sequence of steps). For step
(11), press down the membrane (A) with the finger and re-insert the
ring in the same position it was in when you removed it for dismounting.
3. Adjust the outlet pressure (see chapter "Adjusting the outlet pressure").
All manuals and user guides at all-guides.com
Maintenance
6
2
4
11
A
9
7
8
12
13
14
WAF 04 R
EN