Measuring Diodes (Diode Tester)
Starting from the Resistance position, press the yellow button (secondary functions) to select the
Test Diode function.
Check the circuit to be measured with the contact tips.
Shorted junction indication : beeping for a threshold < 0,050 V
___
Reversed junction indication :
displays.
OL
Display Range
Measurement Range
Measurement Current
Precision
Resolution
Protection
500 V AC or 750 V (DC or Peak)
0
1
18
V
0 - 3,999 V
500 µA
1,5 % ± 2 points
0,001 V