1. Turn off electrical power.
2. Disconnect the GREEN wire labeled (MAIN) from the valve and connect it to the green wire from the ACS-H3V wire
harness.
3. Connect the 3) Connect the BLACK wire with 3/16" flag from the ACS-H3V wire harness to the main burner coil on
the valve, that the GREEN wire was removed from.
4. Disconnect the switch from the 2 brown wires located in the control compartment. Connect the brown wires from the
ignition module to the brown wires from the ACS-H3V wire harness. This switch controls the pilot function (standing
or intermittent). Install the switch into the switch bracket and connect the 2 yellow wires to the switch. Assemble the
provided switch into the switch bracket and connect the switch to the second set of wires. Remove the back side of
the double sided tape and secure the bracket in a convenient location in the valve compartment.
5. Connect the yellow wires with flags to a wall switch/thermostat or remote receiver supplied. Slide the multi lock
connector (supplied) over the yellow wire from the ignition module. Slide the remaining yellow wire from the wire
harness into the connector and snap closed.
6. Slide the multi lock connector (supplied) over the black wire (-) from the battery holder. Slide the remaining black wire
from the wire harness into the connector and snap closed.
Battery
Holder
Battery
Relay
BLACK
BLACK
Transformer
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada
DEXEN ANTI-CONDENSATION SWITCH (ACS-H3V)
INSTALLATION INSTRUCTIONS
Ignition Module
MULTI LOCK
CONNECTORS
YELLOW
BROWN
BROWN
Pilot
ON/OFF
Switch
Burner ON/OFF
Switch / Thermostat
Ignitor
ORANGE
YELLOW
ORANGE
GREEN
MAIN
BROWN
BROWN
BROWN
BROWN
1(866)820-8686
Dexen Gas Valve
ACS-H3V
YELLOW
WIRE
YELLOW
HARNESS
BLACK
YELLOW
W415-3119 / 02.02.22
www.napoleon.com

Publicité

loading

Sommaire des Matières pour Napoleon ACS-H3V

  • Page 1 2. Disconnect the GREEN wire labeled (MAIN) from the valve and connect it to the green wire from the ACS-H3V wire harness. 3. Connect the 3) Connect the BLACK wire with 3/16” flag from the ACS-H3V wire harness to the main burner coil on the valve, that the GREEN wire was removed from.
  • Page 2 1. Coupez l’alimentation électrique. 2. Débranchez le fil VERT marqué (« MAIN ») de la soupape et branchez-le au fil vert de fil d’harnais de l’ACS-H3V. 3. Branchez le fil NOIR avec le cosse à drapeau 3/16” du fil d’harnais de l’ACS-H3V au serpentins électriques principal sur la soupape, dont le fil VERT a été...