Télécharger Imprimer la page

AEG WKL 503 S Manuel D'utilisation Et D'installation page 22

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 25
Installation
1
1 Appliance
2 Safety cap
3 Locking bolt
9.4
Dismounting the appliance
» Remove the safety cap from the locking bolt.
1
1 Appliance
2 Safety cap
3 Locking bolt
» Undo the locking bolt on the wall mounting bracket.
» Lift the appliance up slightly and pull it forwards and away from the wall mounting bracket.
9.5
Power supply
» Ensure the on-site supply cable has an adequate cross-section.
» Ensure a socket or junction box for a permanent power supply is installed at a distance of at least 10 cm from the
side of the appliance.
DANGER Electrocution!
Carry out all electrical connection and installation work in accordance with relevant regulations.
DANGER Electrocution!
The appliance must be able to be separated from the mains power supply by an isolator that disconnects all poles with
at least 3 mm contact separation.
DANGER Electrocution!
Do not install the appliance with a fixed power cable.
Observe the type plate. The specified voltage must match the mains voltage.
10. Troubleshooting
The power cable must only be replaced by a contractor using our original spare parts.
11. Appliance handover
Explain the functions of the appliance to the user. Draw special attention to the safety information. Hand the operating
and installation instructions to the user.