The EL-2601 is a magnetic door and window contact designed for use with Electronics Line
3000's supervised wireless range of receivers.
Installation Instructions
1.
To open the housing, insert a small screwdriver at the bottom of the unit
between the front and back cover and twist the screwdriver to release
the cover.
2.
Remove the divider separating the battery from the contacts on the battery
holder. When you apply power and the Tamper switch is open, the EL-2601
enters Test mode during which a transmission is sent every few seconds. You
can terminate Test mode by closing the Tamper switch. Test mode is
automatically terminated after approximately five minutes. Note: Due to the
occurrence of voltage delay in lithium batteries that have been in storage,
the batteries may initially appear to be dead. In this case, leave the unit in
Test mode for a few minutes until the battery voltage level is stabilized.
3.
While the EL-2601 is in Test mode, set the receiver to Registration mode and
make sure that the EL-2601's LED lights up at least twice. After registration,
close the Tamper switch to terminate Test mode. The receiver allocates a
transmitter number to each registered unit. Write this number and the number of
the zone on the sticker provided. Affix the sticker inside the front cover for future
reference. Note: Alternatively, the EL-2601 can be registered to the receiver
by manually entering the transmitter's serial number.
4.
Before permanently mounting the unit, test the transmitter from the exact
mounting position. If necessary, improve the position of the transmitter. Note:
The alarm is generated by magnet removal at 24 (+/- 0.5) mm and is
cleared by magnet approach at 22 (+/- 0.5) mm.
5.
To remove the PCB, press the PCB release tab and carefully lift the board
and slide the board away from the back cover. Note: When handling the
PCB, do not apply pressure on the antenna.
6.
The EL-2601 is able to operate in three modes: Magnetic Switch, Universal
Transmitter or a combination of the two (see Table 1). If connecting a wired
contact loop (N.C.), connect the terminal block as follows: 1 - Alarm; 2 - GND.
For this purpose, a wiring knockout is provided in the back cover.
7.
If using the rear tamper switch, insert a screw into the rear tamper mounting
hole located in the center of the back cover – see Figure 2. When the detector is
removed from the wall, the screw causes the tamper release to break away from
the back cover and the rear tamper switch is released.
8.
Mount the back cover using two screws and replace the PCB. Use ISO 7050
(ST3.5 x 22) or similar countersunk screws so that the screw head will not
touch the PCB – see Figure 2.
9.
To open the magnet's housing, insert a small screwdriver into one of the pry-
off slots located at either end of the magnet's back cover and lift to separate
from the front cover.
10.
Mount the back cover of the magnet using two screws. Make sure that the
guideline on the magnet is correctly aligned with the guideline on the transmitter.
Note: Do not install the magnet further than 1cm from the transmitter.
11.
Test the transmitter, making certain that the LED is lit when opening the
door/window and again when closing.
12.
Close the front covers of the transmitter and the magnet.
Note: Close the front cover immediately aftereach battery replacement.
Technical Specifications
Antenna: Built-in Internal Whip
Frequency: 868.35, 433.92, or 418 MHz
Power: 3.6V ½ AA Lithium Battery
Caution: Fire, explosion and severe burn hazard!
Do not recharge, disassemble or heat above 100°C.
Current Consumption: 25mA (transmission), 10µA (standby)
Loop Input Voltage Range: 0-15VDC/AC (peak to peak)
RFI Immunity: 40V/m
Operating Temperature: 0-60°C
Figure 1: EL-2601 (cover off)/Figure 1: EL-2601
(sans couvercle) /Figura 1: EL-2601 (sin tapa)
1.
Magnet/Aimant/Magnético
2.
Antenna/Antenne/Antena
3.
Battery Holder/Support de batterie/
Soporte de la Batería
4.
LED Indicator/Indicateur de LED/
Indicador LED
5.
Operation Mode Jumper/Cavalier de mode
opérationnel/Jumper de Modo de Operación
6.
Tamper Switch/Contact d'autoprotection/Llave del
Tamper
7.
Location of Wiring Knockout/Prédécoupe de
passage des câbles/Localización del agujero de
salida de cables
8.
Loop Terminal Block/Borniers/Lazo Bloque de
Terminales
9.
PCB Release Tab/Touche de relâchement
PCB/Traba del PCB
Jumper Position/
Position Cavalier/
Posición Jumper
Pins 1 & 2/
Broche 1 & 2/
Pines 1& 2
Pins 2 & 3/
Broche 2 & 3/
Pines 2 & 3
Jumper Removed/
Cavalier Enlevé/
Jumper Removido
Table 1: Operation Mode Jumper/Tableau 1: Cavalier de Mode
Opérationnel/Tabla1: Jumper de Modo de Operacion
mounting hole/
trou se situant/
agujero de montaje
Figure 2: Rear Tamper /
Figure 2: Autoprotection Arrière/
Figura 2: Tamper Posterior
EL-2601
1cm max.
Operation Mode/
Operation Mode
Operation Mode
Universal Transmitter/
Transmetteur universel/
Transmisor Universal
Magnetic Switch/
Contact Magnétique/
Contacto Magnético
Magnetic + Universal/
Magnétique+ Universel/
Magnético + Universal
PCB
HOUSING/
BOÎTIER/
CAJA
Figure 3: Mounting Screw Position/
Figure 3: Position de la vis de montage/
Figura 3: Posición Tornillo de Montaje

Publicité

loading

Sommaire des Matières pour Electronics Line EL-2601

  • Page 1 EL-2601 English The EL-2601 is a magnetic door and window contact designed for use with Electronics Line 3000’s supervised wireless range of receivers. Installation Instructions To open the housing, insert a small screwdriver at the bottom of the unit between the front and back cover and twist the screwdriver to release the cover.
  • Page 2 3. Pendant que le EL-2601 est en mode de Test, réglez le récepteur en 3. Mientras el EL-2601 esta en modo de Test, coloque el receptor en modo mode d’Enregistrement et vérifiez à...