Manual opening step of the main valve
F33
Compressor manual frequency( Frequency conversion )/(Constant frequency invalid)
F35
DC fan1manual speed*10( Frequency conversion )/(Constant frequency invalid)
F40
Coil temp. when allow defrosting
F41
Coil temp. when exit defrosting
F42
Ambient temp. when allow defrosting
F43
Setting difference between ambient temp. and coil temp.when start defrosting
F44
Temp.difference between ambient and fin when early start defrosting
F45
Compressor operating cycle when enter defrost
F46
Running time of defrosting, 0 represent removal defrosting function
F47
Exhaust sensor type(0:50K-20K 1:5K-5.1K 2:5K-20K)
F48
Compressor frequency when enter the defrosting
"Main valve control mode 1:Automatic control; 2 : Low pressure(Reserved); 3 : Exhaust overheat
F50
degree ; 4 : Return overheat
degree; "
F51
Main valve adjustment cycle
F52
Overheat of main valve A coefficient
F53
Ambient temp. when open the EVI(cooling) (More than 60 show shut down EVI)
F55
Main valve target overheat degree(heating)
F56
Main valve target overheat degree(cooling)
F57
Min. opening step of the main valve(cooling)
F58
Min. opening step of the main valve(heating)
F59
EVI exhaust temp.(cooling)
F78
Extended parameter-parameter number
F79
Extended parameter- setting data
F80
Extended parameter- min. setting data
F81
Extended parameter- max. setting data
4. Utilisation
22
0~500
P
0
0~120
Hz
0
0~200
-
0
-30~15
°C
-10
0~40
°C
15
-30~30
°C
10
0~20
°C
10
0~20
°C
6
1~240
min
40
0~99
min
8
0~2
-
0
0~50
Hz
30
1~5
-
4
10~120
s
60
0~5050
-
508
0~60
°C
60
-10~10
°C
3
-10~15
°C
0
0~480
P
100
0~480
P
100
0~120
°C
70
0~9999
-
0
0~9999
-
0
0~9999
-
0
0~9999
-
0