The connection set consists of a specifically adapted wall power supply (24 V DC).
The connection set supplies the controllers via the RJ12 plug and terminates the RS485 bus at
the same time. For the function of a MC system, one connection set is necessary, regardless of
the number of heating circuits (1-8).
Only use the original wall power supply.
Please observe the instructions of the HeatBloC MC heating circuits and of the MCom controller
for the installation and commissioning.
Risk to life and limb due to electric shock!
 Immediately disconnect the heating circuit from the power supply if it can
 Immediately inform your specialised craftsman!
 Only use original spare parts.
This product is designed for dry indoor rooms only and may not be used outdoors. This product
complies with the relevant directives and is therefore labelled with the CE mark. The Declaration
of Conformity is available upon request. Please contact the manufacturer.
Technical data
Input
Output
RJ12 plug
Bus termination resistor
Operating temperature
Humidity during operation
2
Installation instructions
Connection set for MCom controller
WARNING
no longer be operated safely, f. ex. in the case of visible damage.
100-240 V~
50-60 Hz
0.7 A
21-27 V dc
1.19-0.92 A
25 W (max.)
into socket X6.1 or X6.2 of MCom controller
integrated in plug
0 ... 50 °C
20 % - 90 % relative humidity, non-condensing