IMPORTANT INSTRUCTIONS -
: DRLC707
Model
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
electric shock and injury to person, including the following:
1. Read all instructions before installing or using exhaust fan.
2. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer.
3. Before servicing or cleaning the unit, switch power off at
service panel and lock the service disconnecting means to
prevent power from being switched on accidentally. When
the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the
service panel.
4. Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes
and standards, including fire-related construction.
5. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent back drafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA)
and the American Society for Heating, Refrigeration, and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
CAUTION:
FOR GENERAL VENTILATING USE ONLY. DO
NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS
AND VAPORS.
210572092 Rev. A 8-05
All manuals and user guides at all-guides.com
OPERATING MANUAL
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
SAVE THESE INSTRUCTIONS
6. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
7. Ducted fans must always be vented to the outdoors.
8. This unit must be grounded.
9. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off
power unit.
WARNING:
DO NOT USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL
DEVICE.
10. Acceptable for use over a bathtub or shower when installed
in a GFCI protected branch circuit.
11. NEVER place a switch where it can be reached from a tub or
shower.
WARNING:
www.airkinglimited.com
Exhaust Fan
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
DO NOT USE IN KITCHENS
1 of 12

Publicité

Table des Matières
loading

Sommaire des Matières pour Air King DRLC707

  • Page 1 All manuals and user guides at all-guides.com IMPORTANT INSTRUCTIONS - OPERATING MANUAL : DRLC707 Exhaust Fan Model READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2 All manuals and user guides at all-guides.com INSTALLATION INSTRUCTIONS CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION. Housing SECTION 1 Preparing the Exhaust Fan Joist 1. Unpack fan from the carton and confirm that all pieces are present.
  • Page 3 All manuals and user guides at all-guides.com Supply Ground from house White Hot (Black) Figure 8 Figure 6 2. Wiring Fan/Light together: Run wiring from an approved wall SECTION 4 switch carrying the appropriate rating. One neutral (white), Ducting one ground (green or bare copper), and one hot (black lead connected to the switch).
  • Page 4 All manuals and user guides at all-guides.com SECTION 7 Use and Care CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE SERVICING THE UNIT. 1. Cleaning the Grill: Remove grill and use a mild detergent, such as dishwashing liquid, and dry with a soft cloth. NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS.
  • Page 5: Troubleshooting Guide

    Air King will not be held responsible for any bodily injury or damages to personal property or real estate whether caused directly or indirectly by the product. Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages and some states do not allow limitations on how long an implied warranty lasts, so these exclusions or limitations may not apply to you.
  • Page 6: Replacement Parts Diagram

    All manuals and user guides at all-guides.com REPLACEMENT PARTS DIAGRAM Qty. Description Replacement Part # Qty. Description Replacement Part # Fan Housing 5S1201009 #10 Ground Screw 5S1999002 Mounting Rails 5S1299002 14 ga Ground Wire 5S1999003 Collar 5S1201010 Motor Plate 5S1201014 Damper 5S1201011 Captive Screw...
  • Page 7 All manuals and user guides at all-guides.com INSTRUCTIONS IMPORTANTES – MANUEL D’OPÉRATION : DRLC707 Ventilateur d’Évacuation Modèle LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À...
  • Page 8 All manuals and user guides at all-guides.com INSTRUCTIONS D’INSTALLATION AVERTISSEMENT: VOUS ASSURER QUE L’ALIMENTATION EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER Châssis L’INSTALLATION. SECTION 1 Préparation du Ventilateur d’évacuation Solive 1. Sortir le ventilateur de sa boite et confirmer que toutes les pièces sont présentes.
  • Page 9 All manuals and user guides at all-guides.com d’évacuation. Raccorder le fil de mise à la terre de la maison au fil Vert de la vis de mise à la terre du ventilateur (Figure 8). Utiliser des méthodes de raccordement approuvées pour toutes les connexions.
  • Page 10 All manuals and user guides at all-guides.com SECTION 7 Utilisation et entretien AVERTISSEMENT: VOUS ASSURER QUE L’ALIMENTATION EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER L’INSTALLATION. 1. Nettoyage de la grille: Retirer la grille et utiliser un détergent doux, tel que du liquide pour la vaisselle, puis sécher à l’aide d’un chiffon doux.
  • Page 11: Guide De Dépannage

    GARANTIE LIMITÉE Tous les produits fabriqués par Air King Limited sont garantis pour un an à partir de la date d’achat contre les défauts de main d’œuvre et/ou de matériel. De plus, tous les ventilateurs / évacuateurs, chaufferettes, combinés ventilateur/ lumière et/ou les chaufferettes et les hottes de cuisine sont garantis pour cinq années à...
  • Page 12 All manuals and user guides at all-guides.com REPLACEMENT PARTS DIAGRAM # de pièce # de pièce Qty. Description de remplacement Qty. Description de remplacement Cabinet du ventilateur 5S1201009 Vis #10 de mise à la terre 5S1999002 Traverses de Montage 5S1299002 Fil de mise à...

Table des Matières