Warnings, General Description & Specification for the iVAC Switch Box.
breaker operates, it indicates that the vacuum system has a high start up surge current and is beyond the rating of the iVAC Switch Box.
For higher power vacuums the use the iVAC Contactor is recommended.
Set Up
In a typical set up, the following sequence can be followed.
The Mode Switch is set to OFF.
The power tool is switched off and is then plugged into the Tool Power receptacle.
The vacuum system is plugged into the Vacuum Power receptacle.
The Vacuum Input cord is either plugged into the Auxiliary receptacle or into a separate AC mains outlet, as described above.
The Tool Input cord is plugged into an AC mains outlet.
The Mode Switch is now set to the required mode and the system is ready for use.
Specification
The iVAC Switch Box has received TUV safety approval and conforms to UL STD 508 and is certified to
CSA STDC22.2 No 14.
The iVAC Switch Box has been designed so that it can operate in a continuous mode.
There are three modes of operation. AUTO – OFF - ON
The iVAC Switch Box is designed to operate on 115 Vac. from a 15 Amp circuit.
Turn on delay time 0.5 seconds to 2.0 seconds
Turn off delay time is approximately 6 seconds.
The iVAC Switch Box is warranted to the original consumer purchaser for a period of one year from the date of purchase against defects in material
or workmanship. Proof of purchase is required.
The Company BCTINT Limited obligation under this warranty shall consist of repair, replacement or credit, at its option; provided that the product has
not been misused, abused, altered or damaged as determined by the company.
This warranty does not cover, and is intended to exclude any liability on the part of BCTINT Limited, for any incidental damages, consequential dam-
ages, labour charges or any other costs incurred in connection with the purchase or use of the iVAC Switch Box.
This warranty only applies to iVAC Switch Boxes purchased in Canada or the United States.
BCTINT Limited, 120 Iber Road, Unit 108, Stittsville, ON, K2S 1E9 Canada
Customer Service Toll Free : 1-800-775-5579
Please read the operating instructions before use.
The iVAC Switch Box unit is intended for indoor use, in dry locations only.
This unit may use more than one live circuit.
Do not connect hazardous devices to the 'Vacuum Power' receptacle.
Do not connect to mains circuits that have a capacity of greater than 15 Amps.
General Description and Operation
The iVAC Switch Box is intended to be used in conjunction with a power tool, such as a table saw, router or
sander and an associated vacuum or dust collection system rated at 1HP (4 Peak HP) or less.
The unit has the following Inputs, Outputs and Controls.
It is provided with two input power cords; one for the power tool, Tool Input and one for the vacuum system,
Vacuum
Input.
There are three AC receptacles: Auxiliary, Tool Power and Vacuum Power.
There are three user controls: a Mode Switch and two Circuit Breakers.
Two power cords are provided. Each power cord is individually protected by a 15 Amp circuit breaker.
The Tool Input power cord is used to supply power to the power tool being used and also the Auxiliary recepta-
cle.
The Vacuum Input cord is used to supply power to the vacuum system.
If the combined power requirement of the power tool and the vacuum is less than 15 Amps, then the Vacuum
Input cord can be plugged into the Auxiliary receptacle.
In some situations, the combined power requirement of the power tool and the vacuum system may exceed the
15 Amp rating of the AC mains supply circuit being used. If this situation occurs, then the two input power cords
should be connected to two separate 15 Amp circuits, with separate circuit breakers.
The Auxiliary receptacle is powered from the Tool Input power cord and can be used to power the vacuum
system, as described above.
The Tool Power receptacle is used to provide power to the power tool being used.
The Vacuum Power receptacle is used to provide power to the vacuum system.
The Mode Switch is used to determine the mode of operation of the vacuum system.
There are three modes of operation: Auto – Off – On.
In the Auto mode, when the power tool is activated, power is supplied to the vacuum system after a short Turn
On Delay. When the power tool is turned off, the power to the vacuum system will be maintained for
approximately a further six seconds, in order to clear dust from the work surface.
In the Off mode, power is disconnected from the vacuum system.
In the On mode, power is connected to the vacuum system.
There are two Circuit Breakers on the top surface of the unit; each is rated at 15 Amps. The Tool Breaker is
used to prevent overload conditions at the Tool Power receptacle combined with the Auxiliary
It If the Tool Breaker operates, the configuration needs to be checked. If under these conditions the Vacuum
Input cord is connected to the Auxiliary receptacle, it may be necessary to connect the Vacuum Input cord to
a separate AC mains outlet, which is fed from a different household circuit breaker.
The Vacuum Breaker is used to prevent overload conditions to the Vacuum Input cord. In the event that the
BCTINT Limited
Warnings
Limited 1 Year Warranty
WWW.IVACSWITCH.COM
1-613-599-8988
info@ivacswitch.com
receptacle.
Printed in China—10227-040W

Publicité

loading

Sommaire des Matières pour BCTINT iVAC Switch Box

  • Page 1 BCTINT Limited Limited 1 Year Warranty The iVAC Switch Box is warranted to the original consumer purchaser for a period of one year from the date of purchase against defects in material or workmanship. Proof of purchase is required. The Company BCTINT Limited obligation under this warranty shall consist of repair, replacement or credit, at its option; provided that the product has not been misused, abused, altered or damaged as determined by the company.
  • Page 2 à son choix ; à condition que le produit n'ait pas été abusé, maltraité, changé ou endommagé , comme établi par l'entre- prise. Cette garantie ne couvre pas, et est tenue d’exclure de la responsabilité de la part de BCTINT Limited les dommages accessoires, dommages intérêts, charge de travail ou tous autres coûts contractés par l'achat ou l'usage de la Boîte de Commutateur d'iVac.