Storage & Cleaning - STIL 5511 Notice

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

functions , then press Trigger () to confirm it.
The default emissivity is 0.95, or select other default emissivity:
Emissivity
matt:0.8 , Semi -glossy:0.6 , Glossy:0.3
Select Set value to adj ust the emissivity (0.1 to 1 step .01).
When the temperature reading is outside the
HAL
limit, you will hear a beep sound.
LAL
Select Set Min temp or Set Max item to adjust the limits (step .1).
Language
Selectable Chinese or English .
Backlight
Selectable 5 levels of brightness.
Set the date and time in MM/DD/YYYY (month/day/year) and HH/MM/SS
Set Time
(hour/minute/second) formats.
Time
Turn on Time stamp to save thermal images with real -time stamp.
stamp
Turn off Time stamp to hide date and time on stored thermal images.
Erase
Select Yes, All image! to clear all stored thermal images.
Image
Select Reset to recover the factory setting data.
Reset
Set
Select Use Median Value to reduce noise in an image.
Select No Filter to display real image noise.
parameter
STORAGE & CLEANING
It should be stored at room temperature. The sensor lens is the most delicate part of the thermometer. The lens
should be kept clean at all times, care should be taken when cleaning the lens using only a soft cloth or cotton
swab with water or medical alco hol. Allowing the lens to fully dry before using the thermometer. Do not
submerge any part of the thermometer.
BATTERIES
The thermometer incorporates visual low battery indication as follows:
'Battery OK': measurements
are possible
When the 'Low Battery' icon indicates the battery is low, the battery should be replaced immediately with AA,
1.5V batteries. Please note: It is important to turn the instrument off before replacing the battery otherwise
the thermometer may malfunction.
Dispo se of used battery promptly and keep away from children.
SPECIFICATION
Thermal Image Resolution
Measurement Range
Accuracy (Tamb=20~26°C)
Thermal Sensitivity
Frame Rate
Field of View
Emissivity Range
Focus
LCD (inch)
LCD Type
Image Storage
Memory Type
'Battery Low': battery needs to be
replaced, measurements are still
possible
32*31
-20~250°C (-4~482°F)
±2% of reading, or 2°C(4°F) whichever is greater
0.1°C
9Hz
40*40 deg
0.95 default – adjustable 0.1 to 1 step .01
Focus free
2.8
Color
Stores up to 60000 images/GB
Support 8G micro SD card
254 rue Foch Vaux -le -Pé n il - FRANCE
Matt:0.95 , Semi -
High Alarm (HAL) or Lo Alarm (LAL)
'Battery Exhausted':
measurements are not possible

Publicité

Table des Matières
loading

Table des Matières