Instruction
Sheet
Description: Dual Infinite Switch Kit
Repair Part Number: 12002125
Kit includes:
EGO
4
S2
1 – 74008248
Dual Infinite Switch
To avoid risk of electrical shock, personal injury or death; disconnect electrical power before servicing.
Procedure:
Install dual infinite switch per normal service procedures. If your application requires a jumper
wire(s), use jumper supplied with kit. The diagram below will aid in rewiring.
*On units with a compound connection, the two red wires must be separated. Locate the right front switch
connection (L2). The red wire routed from the right rear element/switch will remain, but the red wire routed from the
left rear element/switch must be disconnected, reterminated and connected to position 2 on the new dual switch.
*On units with an L2 piggyback connection, the two red wires must be separated. Locate the red wire routed to the
L2 supply and connect it to position P2 on the new dual switch. Locate the red wire routed to the element and
connect it to position 2 on the new dual switch.
*On all other applications, the wire connected to the element should terminate to position 2 on the new dual switch.
Page 1 of 1
6/25/2004
TOP
P1
P2
1 – 74008250
4a
S1
1 – 74008249
Jumper Wire
!
WARNING
©2004 Maytag Services
16023363
16023363
Instruction Sheet
(On CVE3400
L2 from RF
goes to 2)
16023363
Replaces 16022704