Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Wiring:

Important!

This unit is a warning device, and it must be connected to its own seperate, fused power point to assure its continued opera-
tion should any other electrical accessory fail.
All wiring should be a minimum of 22 AWG. The positive line must have an in-line 3 amp slow-blow fuse for each directional as shown
in Figure 2.
Isolate unused wires individually.
IN-LINE FUSE
(USER SUPPLIED)
IN-LINE FUSE
(USER SUPPLIED)
IN-LINE FUSE
(USER SUPPLIED)
IN-LINE FUSE
(USER SUPPLIED)
+
-
NOTE: Male PL3 connector is needed but not required. Cut female PL3 connector to hardwire the unit.
Synchronization:
ED3080 series are capable of syncing with other compatible ECCO products by following these steps:
1. Set the desired flash pattern on each unit individually. It is also strongly recommended that the same style of flash pattern be used on all
units to produce the most effective warning pattern. NOTE: Phases A and B for each style of flash pattern in the table denote the relative
timing between units connected in a synchronizing installation. To operate simultaneously, each unit must be set to the same phase
(A + A or B + B); to operate alternately, units must be set to have the opposite phase (A + B or B + A).
2. Connect the yellow sync wires together and check that the units are flashing in a synchronized manner as expected. If a pattern on one
unit appears incorrect, the blue pattern select wire can be used to cycle forward or backward on that individual unit until the correct
pattern is selected. NOTE: This will only change the pattern in the one unit and will not affect the other units connected to the yellow sync
wire.
Flash Pattern Selection:
The ED3080 series directionals can be configured to flash the following patterns by momentarily applying ground to blue wire. The
directional must be powered through the ground and power wires to allow pattern selection.
SWITCH
(USER SUPPLIED)
BLUE - FLASH PATTERN SELECT [MOMENTARY TO (-)]
STOP/TURN
TAIL
GROUND
RED - POWER, COLOR 1
WHITE - POWER, COLOR 2
GRAY - REVERSE
YELLOW - SYNC
RED W/ WHITE STRIPE - STOP/TURN
BROWN - TAIL
WHITE W/ BLACK STRIPE - GROUND
Figure 2
DIRECTIONAL
Page 2 of 4

Publicité

loading