Electronic Low-Voltage Dimmer
RDVELV300, RSELV300 Series
Rated at 120 V~ 60 Hz 300 W
Important Notes
Please read before installing.
1. NOTICE: Use only to control the primary side of electronic transformer-supplied
low-voltage lighting, or in combination with incandescent lamps. To avoid
overheating and possible damage to other equipment, do not use to control
receptacles, fluorescent lighting fixtures, motor-driven appliances, or transformer-
supplied appliances.
2. This product requires a neutral wire in the wallbox. If a neutral wire is not present,
contact a licensed electrician for installation.
3. Install in accordance with all national and local electrical codes.
4. When no "grounding means" exist within the wallbox then the NEC
404.9(B) allows a control without a grounding connection to be installed as a
replacement, as long as a plastic, noncombustible wallplate is used. For this type of
installation, cap or remove the green ground wire on the control and use an
appropriate wallplate.
5. Some fixture manufacturers do not recommend dimming their solid-state transformers.
To determine if a fixture may be dimmed, consult the fixture manufacturer.
6. This control is overload protected. If the rated wattage is exceeded, power to the circuit
will shut off until the control cools. If this occurs, remove excess load from the circuit.
7. In multi-phase applications, use a separate neutral for each phase containing a
dimmed circuit.
8. For new installations, install a test switch before installing the dimmer.
9. Only one dimmer can be used in a 3-way circuit.
10. It is normal for the dimmer to feel warm to the touch during operation.
11. Clean dimmer with a soft damp cloth only. Do not use any chemical cleaners.
Multigang Installations
When installing more than one control in the same wallbox, it may be necessary to
remove all inner side sections prior to wiring (see diagram). Using pliers, bend side
section up and down until it breaks off. Repeat for each side section to be removed.
Removal of dimmer side sections reduces maximum load capacity. Refer to chart below
for maximum dimmer capacity.
Each Control Has Inside
Sections Removed
Dimmer Capacity Chart
Dimmer
No sides
1 side
Rating
removed
removed
300 W
300 W max.
250 W max.
NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts.
Installation
1
Turning OFF Power.
• Turn power OFF at circuit breaker (or remove fuse).
WARNING
2
Removing Wallplate and Switch.
• Remove wallplate and switch mounting screws.
• Carefully remove switch from wall (do not remove wires).
Verify power
is OFF to
switch before
proceeding.
3
Identifying the Type of Circuit.
Different-colored screw (Common).
Actual location may vary.
OR
Ground (Bare
Copper or
Green Wire)
Ground (Bare Copper
or Green Wire)
SINGLE-POLE:
3-WAY:
Insulated wires connected
Insulated wires connected to three screws. One of
to two screws of the
these wires is connected to a screw of a different-
OR
same color. Replace with
color (not green) or labeled COMMON. MARK or
a SINGLE-POLE dimmer.
TAG this wire to identify it when wiring. Replace
See Step 5a.
with a 3-WAY dimmer. See Step 5b.
Wiring Device-Kellems
Hubbell Incorporated (Delaware)
Shelton, CT 06484
1-800-288-6000
www.hubbell-wiring.com
4
English
Disconnecting Switch Wires.
Important Note: Your wall switch may have two wires attached to the same screw (see
illustrations below for examples). Tape these two wires together before disconnecting.
Connect both wires to the dimmer wire in Step 5.
Screw Terminals:
2011, Article
Turn screws to loosen.
®
Important Wiring Information
When making wire connections, follow the recommended strip lengths and combinations for the
supplied wire connectors. Note: Wire connectors provided are suitable for copper wire only. For
aluminum wire, consult an electrician.
Small:
Strip insulation 3/8" (10 mm) for 14 AWG wire
Strip insulation 1/2" (13 mm) for 16 or 18 AWG wire
Use to join one 14 AWG supply wire with one 16 or
18 AWG control wire.
Large:
Strip insulation 1/2" (13 mm) for 10, 12, or 14 AWG
wire
Strip insulation 5/8" (16 mm) for 16 or 18 AWG wire
Use to join one or two 12 or 14 AWG supply wires
with one 10, 12, 14, 16, or 18 AWG control wire.
5
Wiring the Dimmer.
• For installations involving more than one control in a wallbox, refer to the
section on Multigang Installations before beginning.
Note: Wire location will vary by product. Reference wires by color, not
Do Not Remove
5a - Single-Pole Wiring
Outside Sections
Black
White
Middle Control Has Two
Side Sections Removed
Green
Black
120 V~
2 sides
60 Hz
removed
White
200 W max.
5b - 3-Way Wiring
White
Red
Green
Yellow
Shock Hazard. May result in serious injury or death.
Turn off power at circuit breaker before installing the unit.
Red/White
120 V~
60 Hz
6
Mounting Dimmer to Wallbox.
• Form wires carefully into the wallbox, mount and align dimmer.
• Install wallplate.
Start screws.
7
Turning ON Power.
• Turn power ON at circuit breaker (or replace fuse).
Tag
One wire in the
One continuous wire
backwired hole and
to the screw.
one to the screw.
Push-in Terminals:
Looped Wire:
Insert screwdriver. Pull
Turn screw to loosen.
wire out.
Twist wire connector
Be sure no bare wire
Large
Small
location.
• Connect the green dimmer ground
wire to the bare copper or green
ground wire in the wallbox. (See
Important Note 4.)
• Connect the black dimmer wire to the
wire leading to the circuit breaker or
Yellow
fuse box.
• Connect the yellow dimmer wire to
the wire leading to the load.
• Connect the white dimmer wire to
Ground
neutral.
Yellow
Note: To use a 3-Way dimmer (red,
yellow, white, and red/white wires) in
Green
a single-pole application, cap off the
red/white wire and follow instructions
Ground
for single-pole wiring.
Load
• NOTES: Only one dimmer can be
used in a 3-WAY circuit.
Be certain that the 3-way dimmer is
on the line side of the circuit.
• Connect the green dimmer ground
wire to the bare copper or green
ground wire in the wallbox. (See
Important Note 4.)
• Connect the yellow dimmer wire to the
wire removed from the different-
colored screw on the switch (marked
Ground
Tag
or tagged wire). Remove tag from wire.
• Connect the red dimmer wire to either
Tag
of the remaining wires removed from
Red
Yellow
the switch.
Green
• Connect the red/white dimmer wire
Red/
to the remaining wire removed from
White
the switch.
Ground
White
• Connect the white dimmer wire to
Load
neutral.
Align dimmer and
tighten screws.
Made and printed in the U.S.A.
1/
11 P/N 037-207 Rev. A
PDS 2296 1/11
Gradateur à basse tension électronique
RDVELV300, RSELV300 Série
Puissance nominale de 120 V~ 60 Hz 300 W
Remarques importantes
Veuillez lire avant de procéder à l'installation.
1. AVIS : Utiliser seulement pour contrôler l'enroulement primaire d'un transformateur
électronique d'un éclairage basse tension ou en association avec des lampes à
éclairage incandescent. Pour éviter la surchauffe et d'éventuels dommages
à d'autres équipements, ne pas utiliser ce dispositif pour commander l'intensité des
prises de courant, des luminaires à tube fluorescent, des appareils à moteur
électrique ou des appareils alimentés par transformateur.
2. Pour ce produit, un fil neutre doit être présent dans la boîte de sortie. S'il n'y a pas
de fil neutre, consulter un électricien qualifié pour l'installation.
3. L'installer en respectant tous les codes d'électricité nationaux et locaux.
4. Lorsqu'il n'y a pas de « dispositif de mise à la terre » dans la boîte murale, le NEC
2011, Article 404-9(B) autorise l'installation en remplacement d'un gradateur sans
liaison de terre à condition d'utiliser une plaque frontale en plastique non
combustible. Pour ce type d'installation, encapuchonner ou retirer le fil de terre vert
du gradateur et utiliser une plaque frontale correspondante.
5. Certains fabricants d'appareils d'éclairage ne recommandent pas la gradation de
leurs transformateurs à semi-conducteurs (solid state). Pour déterminer si la gradation
d'un appareil d'éclairage est possible, consulter le fabricant de l'appareil.
6. Ces commandes sont dotées d'une protection contre les surcharges. Si le wattage
tight.
est supérieur à celui indiqué, le courant sera automatiquement coupé jusqu'à ce que
is exposed.
le gradateur refroidisse. Dans ce cas, enlever les lampes en surplus.
7. En cas d'installation polyphasée, utiliser un conducteur neutre séparé pour chaque
phase avec un circuit decommande.
8. Pour les nouvelles installations, installer un interrupteur d'essai avant de faire la pose
du gradateur.
9. Un seul gradateur peut être utilisé dans un circuit à 3 voies.
10. Il est normal de sentir une chaleur au toucher du gradateur intelligent lorsqu'il fonctionne.
11. Nettoyer le gradateur avec un chiffon doux et humide seulement. Ne pas utiliser
de nettoyants chimiques.
Installation des gradateurs multiples
Lors de l'installation de plus d'un gradateur dans la même boîte murale, il peut être
nécessaire d'enlever toutes les sections latérales intérieures avant de faire le câblage
(voir ci-dessous). Avec des pinces, replier la section latérale de haut en bas jusqu'à ce
qu'elle se sépare. Répéter pour chacune des sections latérales à enlever. La dépose des
sections latérales du gradateur a pour effet de réduire la capacité de charge maximale.
Consulter le tableau ci-dessous pour connaître la capacité maximale du gradateur.
Tableau des capacités du gradateur
Puissance nominale
Aucun côté
du gradateur
enlevé
300 W
300 W max.
NEC est une marque de commerce de National Fire Protection Association, Quincy, Massachusetts.
Installation
1
Coupure de l'alimentation électrique.
• Couper l'alimentation au disjoncteur (ou retirer le fusible).
2
Dépose de la plaque murale et de l'interrupteur.
• Enlever la plaque murale et les vis de montage de l'interrupteur.
• Retirer délicatement l'interrupteur du mur (ne pas enlever les fils).
3
Identification du type de circuit.
Mise à la terre (fil de
cuivre dénudé ou fil vert)
UNIPOLAIRE :
Les fils recouverts sont
raccordés à deux vis de la
même couleur. Remplacer par
un gradateur UNIPOLAIRE.
Voir l'étape 5a.
Français
®
Ne pas retirer
les sections
extérieures
Les sections intérieures de
Les deux sections latérales
chaque gradateur sont
du gradateur mitoyen sont
enlevées
enlevées
1 côté
2 côtés
enlevé
enlevés
250 W max.
200 W max.
Risque de choc. Peut entraîner de graves blessures
AVERTISSEMENT
ou la mort. Couper l'alimentation au niveau
du disjoncteur avant d'installer l'appareil.
S'assurer que
l'alimentation
électrique est
coupée avant de
commencer.
Vis de couleur différente (neutre).
Son emplacement peut différer
de l'illustration.
OU
Mise à la terre (fil
de cuivre dénudé
ou fil vert)
Étiquette
3 VOIES :
Les fils recouverts sont raccordés à trois vis.
L'un de ces fils est connecté à une vis de
OU
couleur différente (pas verte) ou étiquetée
NEUTRE. MARQUER ou ÉTIQUETER ce fil pour
l'identifier lors du câblage. Remplacer par un
gradateur 3 VOIES. Voir l'étape 5b.
Continué au verso...
Fabriqué et imprimé aux É.-U.
1/11 N/P 037-207 Rev. A
PDS 2296 1/11