Features and guidance
Settings
Cooling Mode – lowers the temperature of your room.
•
Press Mode until the cooling light illuminates.
•
Press Up / Down to adjust the temperature.
•
Press Speed until the desired fan speed light illuminates.
•
Press Sleep, if required, to enable sleep mode. Each hour the
preset temperature will increase by 1°C. The air conditioner
will stop when the room temperature is lower than selected
temperature.
Fan Mode – circulates the air in your room.
•
Press Mode until the Fan mode light illuminates.
•
Press Speed until the desired fan speed light illuminates.
Dehumidifying Mode – reduces the humidity level of your room.
•
Whilst the unit is off, connect the drain hose to the continuous
drain outlet.
•
Place the outlet of the drain hose into a bucket or drain,
ensuring that the end is not submerged in water as this may
cause an air lock. Make sure the hose is at an angle steeper than
200
•
Turn the unit on and then press Mode until the Dehumidifier
light illuminates.
•
The fan speed is not adjustable on dehumidifier mode.
•
The exhaust hose is not needed. Dry air will blow out of the air
exhaust.
Note: Water will not drain from the outlet until the 0.6L internal
tank is full, this can take 4-5 hours.
If used without a drain hose attached, water will be collected in the
internal tank. Auto-shut off will occur when tank is full and 'FT' will
show in the display.
For optimal results, ensure the room temperature is above 18
In dehumidifier mode; below 16
Child lock (S-80, S-150 models) - Disables button use when
enabled
•
Press and hold Lock until the lock symbol lights up.
•
Press and hold again to disable lock feature.
C the unit will enter defrost mode.
o
C.
o
09