Important; Caracteristiques Techniques - Tervis POLARIS D.T. MEMO LD Guide Rapide

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SW2: Sensitivity enabling
SW2 ON
SENSITIVITY MAX.
SW2 OFF
SENSITIVITY MIN.
SW3: programming ENABLE command (Terminal 5)
SW3 ON
Terminal 5 to positive: detector DISABLED
Terminal 5 to negative, or open: detector ENABLED
SW3 OFF
Terminal 5 to negative: detector DISABLED
Terminal 5 to positive, or open: detector ENABLED
SW4: WALK-TEST L1; L2 disabled
L1; L2 enabled for WALK-TEST
SW4 ON
SW4 OFF
L1; L2 disable
4) LED SIGNALLING
- L1 (GREEN): Test IR
- L2 (YELLOW): Test MW
- L3 (RED): ALARM
- Detector DISABLED: memorized ALARM signal on L3
- Detector ENABLED: WALK-TEST signal (with SW4 ON)

IMPORTANT:

- The memory is automatically cancelled when the detector is ENABLED.
- The detector is enabled after 4 second when the ENABLING command
operates.
- The LEDs, at the first power-on, flashes for 1 min. approx.
10

CARACTERISTIQUES TECHNIQUES

Alimentation: 12 Vcc
avec protection contre inversions de
polarité, interférences et surtensions.
Consommation: 65 mA MAX.
Ondulation résiduelle: 1 Vpp.
And fonction detecteur: TIME-OUT 16 sec.
Ouverture: > 90°.
Systèmes optiques:
- Lentille de FRESNEL à basse diffraction à 28 doubles faisceaux.
- Miroir à 3 secteurs pour couverture verticale
Portée: > 12 m.
Elément pyro-électrique: différentiel à double élément.
Section hyperfréquences: stripline avec DRO
Temps ouverture contact reed N.F.: 1 sec. min.
Signalisations:
- ALARME: contact reed N.F. (0,5 A MAX)
- AUTOPROTECTION: contact N.F. (0,5 A MAX).
- TEST et MEMOIRE:
- L1 (VERT): Test canal IR
- L2 (JAUNE): Test canal hyperfréquence
- L3 (ROUGE): Alarme
Effacement memoire:
programmable (normalement positive, ou normalement négative)
Dimensions: 9 x 7 x 5 cm.
Poids: 120 g. environ.
11