• Do not connect system to an unregulated city water system or other external source of pressurized water producing
pressures greater than 35 PSI.
• Pressurized air in system can cause product failure or also cause the dial valve to be blown off which can result in death, serious personal
injury, or property damage. Be sure all air is out of system before operating or testing the equipment.
MAXIMUM OPERATING PRESSURE OF THE FILTER IS 35 PSI. NEVER SUBJECT THE FILTER TO ANY OPERATING PRESSURE
EXCEEDING 35 PSI.
• This fi lter operates under high pressure. When any part of the circulating system, i.e., fi lter, pump, valve(s), etc. is serviced, air can enter the
system and become pressurized when the system is restarted. Pressurized air can cause product failure or also cause the dial valve to be
blown off which can result in death, serious personal injury or property damage. To avoid this potential hazard, follow all of the instructions
in this manual.
To minimize risk of severe injury or death the fi lter and/or pump should not be subjected to the piping system pressurization
test. Local codes may require the pool piping system to be subjected to a pressure test. These requirements are generally
not intended to apply to the pool equipment such as fi lters or pumps.
Jandy™ pool equipment is pressure tested at the factory.
If however this WARNING cannot be followed and pressure testing of the piping system must include the fi lter and/or pump
BE SURE TO COMPLY WITH THE FOLLOWING SAFETY INSTRUCTIONS:
• Check all clamps, bolts, lids, lock rings and system accessories to ensure they are properly installed and secured before testing.
• RELEASE ALL AIR in the system before testing.
• Water pressure for test must NOT EXCEED 35 PSI.
• Water temperature for test must NOT EXCEED 100° F (38° C).
• Limit test to 24 hours. After test, visually check system to be sure it is ready for operation.
Notice: These parameters apply to Jandy equipment only. For non-Jandy equipment, consult equipment manufacturer.
General Safety Instructions
ATTENTION INSTALLER:
This manual contains important information about the installation, operation and safe use of this product. This information
should be given to the owner/operator of this equipment.
1. Use equipment only in a pool or spa installation.
2. Before repositioning valve(s) and before beginning the assembly, disassembly, or removal or adjustment of the dial valve, or any other
service of the circulating system; (A) turn the pump off and shut off any automatic controls to ensure the system is not inadvertently started
during servicing; (B) open the air release valve; (C) wait until all pressure is relieved (air will have stopped fl owing from the air release valve).
3. Maintain circulation system properly. Replace worn or damaged parts immediately.
4. Be sure that the fi lter is properly mounted and positioned according to these installation instructions.
5. Do not pressure test above 35 PSI. Pressure testing must be done by a trained pool professional.