INSTALL EXHAUST DIFFUSERS
4" ROUND
INSULATED
FLEXIBLE DUCT
TO
VENTILATOR
CEILING
DRYWALL
DIFFUSER
Follow instructions packed with diffuser(s). General instructions:
1. Cut hole(s) in ceiling drywall and install diffuser(s).
2. Connect insulated ductwork to diffuser(s) and use duct tape or
clamp (available separately) to seal connection(s).
3. Rotate center of diffuser(s) counterclockwise to fully open for
maximum air flow. Reduce air flow by rotating center of
diffuser(s) clockwise to desired opening. A balancing damper
(available separately) can be used to adjust airflow.
SERVICE PARTS
Models MP100, MP140 & MP200
KEY
PART
NO.
NO.
1
99150591
Screw, #10 x 7/8" (4 required)*
2
97011410
Housing Assembly (includes Key No. 7)
3
98005512
Wiring Adapter Plate
4
99150471
Ground Screw, #10-32 x 1/2"
5
97008575
Wiring Harness
6
99260477
Whiz Nut, 1/4-20 (2 required)*
7
99420470
Grille Nut (2 required)
8
98005513
Outlet Box Cover
9
99400035
Strain Relief Bushing
10
97011394
Blower Wheel (MP100)
97011395
Blower Wheel (MP140)
97011396
Blower Wheel (MP200)
11
97011361
Blower Housing (MP100)
97011362
Blower Housing (MP140)
97011363
Blower Housing (MP200)
12
99100412
Motor Mounting Rubber (2 required)
13
97011400
Motor (MP100) (includes Key No. 16)
97011411
Motor (MP140) (includes Key No. 16)
97011402
Motor (MP200) (includes Key No. 16)
14
95000963
Motor Cup
15
99170245
Screw, #8 x 3/8" (10 required)*
16
97011403
Capacitor (MP100)
97011412
Capacitor (MP140)
97011405
Capacitor (MP200)
17
97011406
Cover
18
99110942
Inlet Cover (covers unused inlet ports)
**
97011407
Blower Assembly Complete (MP100)
(includes Key No.s 10 thru 16)
**
97011413
Blower Assembly Complete (MP140)
(includes Key No.s 10 thru 16)
**
97011409
Blower Assembly Complete (MP200)
(includes Key No.s 10 thru 16)
* Standard Hardware - May be purchased locally.
** Not shown assembled.
Broan warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE
ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one-year period, Broan will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have
been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan), faulty installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation
may not apply to you.
BROAN'S OBLIGATION TO REPAIR OR REPLACE, AT BROAN'S OPTION, SHALL BE THE PURCHASER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN SHALL NOT BE
LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion
or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty
service, you must present evidence of the original purchase date.
DESCRIPTION
Always order replacement parts by "Part No, - not by "Key No."
BROAN ONE YEAR LIMITED WARRANTY
USE AND CARE
WARNING: DISCONNECT ELECTRICAL POWER AND LOCK
OUT SERVICE PANEL BEFORE CLEANING OR SERVICING
THIS UNIT.
CLEANING
DUCT
A continuously operating in-line ventilator needs to be cleaned
TAPE
once a year to assure proper performance.
OR
CLAMP
Remove cover and carefully vacuum blower and inside of hous-
ing. Be careful not to bend or otherwise damage blower wheel.
Diffusers and intake vents can be vacuumed and/or wiped clean
with a damp cloth.
MOTOR LUBRICATION
The motor is permanently lubricated. Do not oil or disassemble
motor.
15
10
1
18
In the U.S., contact: Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453)
In Canada, contact: Broan-NuTone Canada, Inc., 1140 Tristar Drive, Mississauga, Ontario L5T 1H9 (1-888-882-7626)
17
13
12
6
11
9
8
15
7
15
3
4
14
12
15
16
5
2
99041951J