Water Systems
INSTALLATION RECORD
Date of Installation:
Model Number:
Serial Number:
Tank-Cistern location:
Pump Setting:
Wire Gauge:
Riser Pipe Size:
I. INSTALLATION & OPERATING INSTRUCTIONS
It is important that all submersible pumps be installed by expe-
rienced persons and that all electrical connections comply with
the relevant electrical supply authority requirements.
The electrical connections and checks must
be made by a qualified electrician and
comply with applicable local standards.
These instructions are provided for guidance only, and assume
a familiarity with submersible pump installation and commis-
sioning procedures.
II. IMPORTANT!!!
The MINISUB is designed to pump effluent from a cistern. If
the fluid from the cistern or any plumbing system freezes, the
pump will be severely damaged.
The MINISUB is suitable to pump effluents that don´t contain
dissolved gases.
The pump cannot be used for inflammable,
explosive or dangerous liquids.
III. INSPECT THE EQUIPMENT
Before going on the job, open all packages and check all equip-
ment to be certain everything is included and that no parts have
been damaged during shipment. The pump should be checked
for visible damage and nameplate inspected to be sure they are
the correct voltage and phase.
Ensure the motor voltage and phase
matches the supply voltages & phase.
INSTALLATION AND OPERATING INSTRUCTIONS
Above Ground
Below Ground
MINISUB
4" Effluent Bottom Suction Pump
Carefully store this manual.
These Instructions must be
delivered with the pump to the
operator.
WARNING: Read this manual
carefully. Failure to follow these
instructions and comply with all
applicable codes may cause
serious body injury and/or
property damage
IV. INSTALLATION
NOTE: FOR SEALING OF PIPE THREADS ONTO YOUR MINISUB
USE THREAD TAPE ONLY. DO NOT USE PIPE SEALING COM-
POUND AT ALL.
All pipe and fittings must be suited to the
maximum pressures available from the pump.
DANGER: Electric Shock Risk - When
installing, please ensure electro-pump is
disconnected from the electrical supply.
DANGER: Electric Shock Risk – MINISUB
pumps are not suitable for use in a swimming
pool and the relevant cleaning and servicing
operation.
1. Safety Cable
Do not use the electric cable to lower, lift or transport the pump.
As a precautionary measure, a safety line should be connected
to all pumps regardless of the type of drop pipe used. This line
should be fastened to the pump and at the top of the cistern.
2. Depth of Installation
Install the pump at least 8" from the bottom of the cistern to
avoid pumping sand, mud, etc.
Special feature of the MINISUB is that its body height is only
22" and it allows use of these pumps in cisterns with low water
depth.
It is advisable to install an automatic level controls to prevent
the electric pump from running dry and a pressure gauge to
verify its performance during operation.

Publicité

Table des Matières
loading

Sommaire des Matières pour Pearl MINISUB

  • Page 1 Before going on the job, open all packages and check all equip- ment to be certain everything is included and that no parts have Special feature of the MINISUB is that its body height is only been damaged during shipment. The pump should be checked 22”...
  • Page 2 10´, when using rigid piping. are to be installed. The MINISUB pumps have a built-in thermal protection. The pump stops if an overload condition occurs and the motor After purchasing the pump, check that it has not been damaged restarts automatically after it has cooled down, therefore pump during transportation.
  • Page 3: Frost Protection

    2.1 Frost protection While MINISUB pumps do not require regular maintenance, it is a good practice to monitor the conditions and performance of If the pump has to be stored after use, it must be stored in a the pump. This diagnosis may be carried out by checking the frost-free location.
  • Page 4 IX. PERFORMANCE CHART MSP 07 MSP 05 PD WATER SYSTEMS LLC 2310 W. 76TH ST. HIALEAH, FL 33016. TEL: (954) 474 9090 www.pearlwatersystems.com...
  • Page 5 IV. INSTALACIÓN Solamente electricistas calificados pueden efectuar las conexiones e inspecciones NOTA: PARA SELLAR ROSCAS DE TUBERIAS A SU MINISUB eléctricas y estas tienen que cumplir con las UTILICE SOLAMENTE CINTA DE SELLADO. NO USE NINGUN normas locales.
  • Page 6: Conexiones Eléctricas

    Una característica especial de la MINISUB es que su altura es protección externa adicional. de solamente 22” lo que permite su uso en cisternas con poca profundidad de agua. Los cables de extensión eléctricos tienen que tener una sección mínima de H07 RN_F. Proteger el conector y las conexiones de Se aconseja la instalación de controles de nivel automático para...
  • Page 7: Protección Contra Las Heladas

    8 días de la fecha de compra. No exponer la bomba a impactos innecesarios ni a golpes. Aunque MINISUB no requiera mantenimiento regular, es buena norma monitorear las condiciones y el rendimiento de la bomba.
  • Page 8: Diagrama De Rendimiento

    IX. DIAGRAMA DE RENDIMIENTO MSP 07 MSP 05 PD WATER SYSTEMS LLC 2310 W. 76TH ST. HIALEAH, FL 33016. TEL: (954) 474 9090 www.pearlwatersystems.com...
  • Page 9: Instructions D'instalation Et D'utilisation

    . Avant de commencer le travail, ouvrez tous les paquet et vérifiez tous les équipements pour vous assurer que tout La particularité du MINISUB est que sa hauteur de corps n’est est inclus et qu’aucune pièce n’a été endommagée pendant que de 22”...
  • Page 10 Les rallonges électriques doivent avoir une section minimale pendant son processus de fabrication. de H07 RN_F. La prise et les connexions doivent être protégées Les pompes MINISUB sont fournies par l’usine dans un contre les projections d’eau. emballage approprié dans lequel elles doivent rester jusqu’à...
  • Page 11: Protection Contre Le Gel

    2. Stockage et manutention Bien que les pompes MINISUB ne nécessitent pas d’entretien régulier, il est recommandé de surveiller les conditions et les La pompe ne doit pas être exposée à la lumière directe du performances de la pompe. soleil. Si la pompe a été déballée, elle peut être stockée Ce diagnostic peut être effectué...
  • Page 12 IX. TABLEAU DE PERFORMANCE MSP 07 MSP 05 PD WATER SYSTEMS LLC 2310 W. 76TH ST. HIALEAH, FL 33016. TEL: (954) 474 9090 www.pearlwatersystems.com...

Table des Matières