IMPORTANT SAFETY INFORMATION ABOUT
A self contained LP-gas cylinder for use with this appliance must have a capacity of
20 lbs. and must be equipped with a Type 1 connector and an OP D (overfill
protection device). See Figure 1.
The LP-gas supply cylinder to be used must be constructed and marked in
accordance with the specification for LP- gas cylinders of the U.S. Department of
Transportation (DOT) or the National Standard of Canada, CAN/CSA-B339, Cylinder,
Sphere and Tubes for the Transportation of Dangerous Goods.
The cylinder supply system must be arranged for vapor withdrawal.
The cylinder used must include a collar to protect the cylinder valve.
This appliance shall be used only outdoors in a well-ventilated space
and shall not be used in a building, garage or any other enclosed space.
When this appliance is not is use, the gas must be turned off at the
supply cylinder.
Storage of this appliance indoors is permissible only if the
cylinder is disconnected and removed from the appliance.
Cylinders must be stored outdoors in a well-ventilated area out of the
reach of children .Disconnected cylinders must have threaded valve plugs tightly
installed and must not be stored in a building, garage or any other enclosed areas.
Storing cylinders indoors or in poorly ventilated spaces outdoors can result in
serious bodily injury and/or death.
CSA (Canadian Standards Association) certified to ANSI Z83.26•CSA 2.41-
2016 " Outdoor Decorative Gas Appliances".
INPUT
Propane Regulator
Pressure
Natural Gas Minimum
Inlet Pressure
Clearances to
combustible surfaces
P015-900
PROPANE (LP) GAS
Figure 1
SPECIFICA TIONS
46,000 Btu/hr
11 inches water column
7 inches water column
Sides: 24in./61cm
Top: 36 in. / 91.44 cm