Installation Instructions for IRiS E4 Series Elements
WARNING
RISK OF ELECTRICAL SHOCK
Disconnect power at fuse or
circuit
breaker
before
installing or servicing.
E4DL
General Installation for All Elements:
Elements are shipped with retention springs located for ½ - 1 inch thick ceiling installations (Fig.1). For ceilings greater than 1 inch thick the springs must be
relocated. To relocate spring, push spring body to one side of bracket compressing the coils. Pivot spring body so that it is disengaged from the tabs (Fig.2).
Remove spring from bracket (Fig. 3). Install spring in upper position by hooking the short legs of the spring on the inside of bracket (Fig. 4) and sliding spring
body over tab (Fig. 5). Compress spring coils and guide spring body over second tab (Fig. 6). Note: Spring relocation does not apply to E4AA and E4LWW
Elements.
Rimless Elements – E4DL, E4AA, E4MR, & E4LWW elements (non-self flange) may be used in conjunction with optional plaster lathing ring by removing the
metal trim ring. Remove metal trim ring as described below. Pinhole versions must be ordered with the suffix RL for the rimless option.
Remove overspray protector from the platform and discard.
Fold torsion springs upward and insert element into platform (Fig. 7). Push the element firmly against the ceiling (Fig. 8). If element flange is NOT seated
completely against ceiling, pull the element away from the platform. Check for possible obstructions or improperly oriented element.
Adjustable Accent Elements: E4AA Series, E4PIN Series, E4RPIN Series, and E4LWW Series
For installations with module MA4xx horizontal and vertical aiming adjustments must be completed and locked prior to inserting the element. To tilt
mechanism insert screwdriver through access hole in adjustment mechanism plate and into locking screw (Fig. 9). Loosen locking screw by rotating counter
clockwise. Pivot screwdriver to achieve desired beam angle (Fig. 10) and tighten screw. To rotate mechanism, loosen clamping screw (Fig. 11). Insert
screwdriver into rotation tab and rotate assembly to desired position. Retighten clamping screw.
Pin Hole Reflector Cone: E4PIN Series and E4RPIN Series
Elements are supplied with two reflector cones and are shipped with the angle cut cone attached. To replace angle cut cone with the enclosed down light
cone, remove clips (Fig. 12), replace with down light cone (Fig. 13), and reinstall clip (Fig. 14). The E4PIN element has a removable black oculus that allows a
wider beam spread if desired. The oculus can be removed by following the instructions for replacing the cone as described above.
Painting Metal Trim Ring:
For elements with metal trim rings, the trim ring may be removed and painting to match ceiling color in the field:
Step 1
Remove clips using a small screw driver for leverage.
Step 2
Remove the metal trim ring from element.
Step 3
Clean and prepare surface for painting.
Step 4
Paint as desired. Note: Paint must be rated for 90°C. Contact reputable paint manufacturer for recommendations.
Step 5
After paint has thoroughly dried reassemble in reverse order.
WARNING
RISK OF FIRE
Supply conductors (power wires) connecting
the fixture must be rated minimum 90°C. If
uncertain, consult an electrician.
E4AA
E4MR
Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269 • 770.486.4800 • 770.486.4801
Use only elements provided by IRiS Lighting
Warning:
Systems. Use of other manufacturer's reflectors
voids the Underwriters Laboratories listings and
CSA certification and could constitute a fire
hazard.
For your safety read and understand instructions
Caution:
completely before beginning installation.
E4LWW
E4PIN
E4RPIN
704399INS