1. ASENNUS
Sääntelymoduuli Slave SUPERIOR
1
0-10
0-10
24VAC
VDC
GND
VDC
GND
1
2
24V
GND
23 24
25 26
25 26
1
2
2
0-10V
24VAC
0-10V
24VAC
MIX. POINT / OUTDOOR
MIX. POINT / OUTDOOR
MIX. POINT / OUTDOOR
POWER SUPPLY
Vanne/ Groupe Exterieur DX
Vanne/ Groupe Exterieur DX
Alimentation
Vanne/ Groupe Exterieur DX
UNIT DX
UNIT DX
MIX POINT
vanne
HEATER/
HEATER/
HEATER/
VENT-INT
VENT-EXT
PREHEATER
24VAC
24VAC
POSTHEATER
PREHEATER
24VAC
REC/BYP
POSTHEATER
REC/BYP
RPM
T-EXT-1
COOL/PUMP
~
~
~
~
~
~
COOL/PUMP
T-EXT-1
GND
COOL/PUMP
PWM
GND
GND
PWM
GND
+SSR -SSR
1
2
0-10V
GND
GND
1
+SSR -SSR
2
0-10V GND
0-10V GND
(TC)
1
2
0-10V
0-10V
GND
0-10V
GND
0-10V
GND
16 17 18 19 20 21 22 23 24
25 26 27 28 29
30
31
32
33
25 26 27 28 29
34
35 36 37 38 39 40 41 42 43
30
31
32
33
34
35 36 37 38 39 40 41 42 43
FUSE
(VENT-INT)
FUSE
(PERIPHERY)
72 71
72 71
70 69
68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51
68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51
72 71
70 69
LO
L
LO
L
LO
N
RUN
RUN
COOL/HEAT
COOL/HEAT
ALARM
RUN
ERROR
DEFROST EXTERNAL
ERROR
DEFROST EXTERNAL
230VAC
230VAC
230VAC
OUTPUT
HEAT PUMP
HEATER
OUTPUT
OUTPUT
HEAT PUMP
HEAT PUMP
HEAT PUMP
ON/OFF
ON/OFF
FLAP-INT
FLAP-EXT
W. PUMP
230VAC
CONTACT
EXTERNAL
CONTACT
EXTERNAL
WATER
POMPE
CONTROL
CONTROL
EXTERNE
EXTERNE
PUMP CONTROL
DE CIRCULATION
OUTPUT
OUTPUT
OUTPUT
ON/OFF
ON/OFF
72 71
3
4
76 75
63 64
63 64
6
4
DX = ON/OFF
DX = ON/OFF
7
7
11
11
(Sortie pour unité
(Output for outdoor unit)
Commande
Commande
exterieure)
á distance
á distance
E
VCS-R4-SU-*-
2
3
Control panel
Control panel
boitier de commande
boitier de commande
0-10
VDC
GND
24
23
22
20
19
25 26
49 50
49 50
EXT. SENSOR
EXT. SENSOR
3
2
3
Capteur Externe.
Capteur Externe.
0-10V
(two-wire shielded cable)
(two-wire shielded cable)
(two-wire shielded cable)
Câble deux fils blindé
Câble deux fils blindé
Câble deux fils blindé
UNIT DX
T-WATER T-WATER T-ROOM
PREHEATER
24VAC
POSTHEATER
T-WATER T-WATER T-ROOM
REC/BYP
T-EXT-2
T-EXT-3
T-INT-1
T-INT-2
T-EXT-1
T-EXT-2
T-EXT-2
~
T-EXT-3
~
T-INT-1
T-INT-2
+SSR -SSR
-OUT
-OUT
1
2
0-10V
GND
0-10V GND
9
30
31
32
33
34
35 36 37 38 39 40 41 42 43
44 45 46 47 48 49 50
44 45 46 47 48 49 50
SWO
SWO
DATA
DATA
70 69
68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51
1
2
PRESENCE
1
2
PRESENCE
COOL/HEAT
IN GND
REC ERR
ERROR
DEFROST EXTERNAL
REC ERR
FIRE
FIRE
BOOST
BOOST
FIRE
15VAC
15VAC
SENSOR
SENSOR
HEAT PUMP
HEAT PUMP
CO2/RH/EXT
CO2/RH/EXT
ON/OFF
PIR
PIR
CONTACT
EXTERNAL
CONTACT
CONTACT
FIRE
CONTACT
FIRE
FIRE
CONTACT
CONTACT
ERROR
CONTROL
ERROR
EXTERNE
INCENDIE
INCENDIE
INCENDIE
CONTACT
ERREUR
CONTACT
ERREUR
BOOST
BOOST
ON/OFF
5 6
7
8
62 61
63 64
62 61
59 60
62 61
57 58
57 58
5
6
BOOST
BOOST
12
12
13
13
11
Commande
CMSI
CMSI
CMSI
á distance
2VV.Creating innovative solutions for you and your business since 1995.
S
VCS-R4-SU-*-
GTC
GTC
ou
ou
or
or
Control panel
boitier de commande
ModBUS RTU via
ModBUS RTU via
Rs485
Rs485
49 50
EXT. SENSOR
3
Capteur Externe.
J1/J2
J1/J2
J1/J2
1
T-WATER T-WATER T-ROOM
T-EXT-3
T-INT-1
T-INT-2
-IN
-IN
-OUT
-IN
FILTER
FILTER
2
9
9
3
10
10
JP1
JP1
INT
INT
4
LED1
LED1
44 45 46 47 48 49 50
5
6
SWO
7
DATA
8
9
1
2
PRESENCE
IN GND
IN GND
REC ERR
BOOST
15VAC
SENSOR
CO2/RH/EXT
PIR
CONTACT
ERROR
CONTACT
ERREUR
BOOST
9
10
11
59 60
59 60
57 58
7
BOOST
!
!
14
14
14
12
13
V
VCS-R4-SU-*-
in control module
GTC
ou
or
ModBUS RTU via
Rs485
LPHW-anturi (sisältyy toimitukseen)
FILTER
Signaali SLAVE-yksikölle
9
Jäätymisenestotermostaatti (NC)
10
JP1
INT
Ulkoinen ohjaus - PÄÄLLE / POIS
LED1
Huonetermostaatti (tulo)
OVAKOSKETTI (sisääntulo)
Signaali MASTER-yksiköltä
Vesiventtiilin säätö (0-10 V)
SLAVE
SLAVE
1
6
1
2
7
2
3
8
3
4
9
4
5
10
5
!
in Steuermodul
24V
GND
0-10V
24V
8
GND
HEAT
0-10V
6
7
8
9
A
7