LP Conversion Kit Instructions for D3/300 Series
Gas Self Clean and Dual Fuel Range
W A R N I N G
The conversion must be performed by a qualified
installer or gas supplier in accordance with the
manufacturer's instructions and all codes and
requirements of the authority having jurisdiction. Failure to
follow ALL instructions could result in serious injury or
property damage. The qualified agency performing this
work assumes responsibility for this conversion.
The pressure regulator and the burner orifices are set for Natural
gas. To use Liquid Propane gas, the regulator and burner orifices
must be converted.
To convert the range to LP gas, follow these instructions:
1. Disconnect all electrical power at the main circuit breaker or
fuse box.
2. Shut off the gas supply to the range by closing the manual
shut-off valve.
Converting the Pressure Regulator
1. Locate the pressure regulator which can be found on the back
of the range on the right hand side if facing the back of the
range.
2. Unscrew the hex nut cap from the top of the regulator.
3. Unsnap the plastic plunger from the hex nut.
4. Reverse the plunger and reinstall onto the hex nut by
pressing firmly.
Note: Plunger is marked "Nat" and "LP". Converted fuel type will
be shown on the lower portion of the plunger.
Apply sideways
finger pressu re
to remove pin
from cap
NAT
D3
Burner
Left front (dual)
High
Natural
Low
Left rear
Center
NAT
Right front
Right rear
LP
LP
Bake
Broil
300 Series
Burner
LP
Left front
Left rear
Center
Right front
Right rear
Bake
Broil
Converting the Surface Burners
1. Remove the top grates, burner caps, and burner heads.
Burner
grate
Burner
cap
Burner
head
Burner
base
2. Using a 9/32" or 7 mm nut driver remove the top burner
orifices. These may be accessed through the opening in the
burner base.
Note: Save these orifices for future conversion back to Natural gas,
if required.
3. Locate the proper LP surface
burner orifices included with
the kit according to the chart
below.
4. Install the orifices in their
correct location. To prevent leakage, make sure the orifice
spuds are securely screwed into the burner base.
BTU Rate Orifice Size
1.09
15,800
0.33
1,000
6,500
0.79
8,000
0.87
15,000
1.19
11,000
1.01
30,000
1.68
14,500
1.03
BTU Rate Orifice Size
1.19
15,800
6,500
0.79
8,000
0.87
15,000
1.19
11,000
1.01
30,000
1.68
14,500
1.03
Orifice
spud
Orifice
size
Orifice
0.79
0.87
1.01
1.09
1.19
0.33
0.79
0.87
1.01
1.19
1.19

Publicité

loading

Sommaire des Matières pour LP D3 Serie

  • Page 1 To prevent leakage, make sure the orifice spuds are securely screwed into the burner base. Note: Plunger is marked “Nat” and “LP”. Converted fuel type will be shown on the lower portion of the plunger. Burner BTU Rate Orifice Size 0.79...
  • Page 2 1. Use a screwdriver to loosen the air shutter screw. 5. Remove screws securing bake burner to oven burner box. 2. Adjust the air shutters for LP gas by rotating the shutter to the 6. Loosen air shutter screw and adjust opening on burner to 3/8”...
  • Page 3 4. Retournez le piston plongeur et réinstallez-le sur l’écrou en vous que l’embase des orifices est solidement vissée sur la base pressant fermement. du brûleur. Remarque : Le piston plongeur est marqué « Nat » et « LP ». Le 0.79 0.87 1.01 type de combustible converti apparaîtra sur la partie inférieure...
  • Page 4 Remarque : Pour effectuer la reconversion au gaz naturel, procédez inversement. Remarque : Une fois la conversion LP/Propane terminée, 3. Débranchez le câble de l’allumeur. remplissez l’étiquette de conversion et placez-la à côté de 4. Utilisez une clé de 1/2 po (12 mm) pour enlever le capot de l’étiquette des valeurs nominales.

Ce manuel est également adapté pour:

300 serie