Télécharger Imprimer la page

Fairview GAS-FLO 2095 Instructions D'installation page 2

Publicité

Les langues disponibles

Les langues disponibles

F
AIRVIEW
1170 Invicta Drive, Oakville ON L6H 6G1
INSTALLATION INSTRUCTIONS FOR P.O.L. TO
CYLINDER PRIMUS CONNECTION
Failure to follow these instructions may result in an explosion or
fire that may cause property damage, serious injury or death.
1. READ ALL INSTRUCTIONS PRIOR TO INSTALLATION AND USE of this POL To Cylinder Primus Adapter. Installation
or disconnection of adapter and leak testing must take place outdoors in a well ventilated area only.
2. DO NOT make modifications to this adapter, if this adapter does not fit return to place of purchase.
3. Examine the POL To Cylinder Primus Adapter for damage. If damaged return to original place of purchase and
exchange for a complete new adapter.
INSTALLATION OF POL TO CYLINDER PRIMUS ADAPTER.
4. Ensure gas is turned "off" at cylinder by turning cylinder valve handle clockwise.
5. Move propane cylinder to an open well ventilated outdoor area prior to connecting the adapter.
6. Remove the plastic thread protector from the P.O.L. fitting of the adapter.
7. DO NOT connect if P.O.L. nipple-O-ring is missing or damaged. Obtain and install a new nipple-O-ring prior to
connecting to propane cylinder valve outlet.
8. Using the plastic hand wheel connect the P.O.L. connection to the cylinder valve outlet by turning P.O.L. fitting
counterclockwise (left hand thread) until hand tight. Use hand wheel to tighten.
NOTE: The connection at the cylinder valve is a left hand thread. Turn the nut counterclockwise to install the
P.O.L. fitting into the cylinder valve outlet.
If you cannot complete the P.O.L. connection, disconnect the connection and repeat step 8. If you
are still unable to complete the connection, do not use this POL To Cylinder Primus Adapter.
CHECK FOR LEAKS:
9. Before using your POL To cylinder Primus Adapter, check all connections for leaks using a mild soapy water solution.
DO NOT use matches, lighters or flame to check for leaks, you could cause an explosion.
10."Slowly" open the propane cylinder valve by turning the handle counterclockwise. Apply mild soapy solution to all
connections and look for bubbles. A expanding bubble or bubbles indicate a leak. Repair all leaks prior to using POL To
Cylinder Primus Adapter.
11.If you cannot stop a leak by additional tightening of the connection turn "off" the propane cylinder valve Disconnect the
leaking connection and re-install as per step 8. Recheck for leaks as per step 10.
To prevent fire or explosion hazard when leak testing:
(1) NO SMOKING. DO NOT use or permit sources of ignition in the area while conducting a leak test.
(2) Conduct leak test outdoors in well ventilated area.
(3) DO NOT use matches, lighters or flame to check for leaks.
(4) DO NOT use POL To Cylinder Primus Adapter until any leaks are corrected
(5) If you are unable to stop a leak, shut-off the propane supply at the cylinder valve. Remove the
POL To cylinder Primus Adapter from the propane cylinder valve outlet.
(6) Call a Gas Appliance Serviceman or your local propane gas supplier.
NOTE: The male cylinder thread connection outlets are equipped with a backcheck valve that prevents the flow of
gas until the connection is made with the proper hose extension fitting.
DO NOT insert foreign objects into the backcheck valve of the male cylinder thread connections. If
cylinder valve is turned "on" high pressure gas will escape which could result in an explosion or fire
L
.
TD
DANGER
Consult your local propane gas dealer.
that may cause property damage, serious injury or death.
• COQUITLAM, B.C. (LOCAL AREA) TOLL FREE: (888) 294-7104 • EDMONTON, ALBERTA TOLL FREE: (888) 441-9883
• SASKATOON, SASKATCHEWAN TOLL FREE: (866) 866-9198 • WINNIPEG, MANITOBA TOLL FREE: (888) 290-3821
• MISSISSAUGA, ONTARIO TOLL FREE: (800) 800-4018 LAVAL, QUEBEC TOLL FREE: (800) 663-334
CAUTION
DANGER
WARNING
• DIEPPE (MONCTON), NEW BRUNSWICK TOLL FREE: (800) 561-8551
www.fairviewfittings.com service@fairviewfittings.com
• WOBURN, MASSACHUSETTS CONTINENTAL U.S.A.: (800) 695-3101
WHEATFIELD, NEW YORK CONTINENTAL U.S.A.: (800) 688-4088 • ELKHART,
INDIANA 46514 CONTINENTAL U.S.A.: (877) 459-0700
Form: PM-INSTRUCT-2095