The assembly and installation must be carried out in accordance with the national
regulations of the country of use.
•
The stove should be installed away from all flammable materials and at least 5 cm away
from walls.
•
The installation location must have sufficient space and ventilation.
•
The assembly and installation must, in all cases, comply with the safety requirements in
force.
•
Remove all protective film and stickers before use.
•
Refer Figure 1 for the illustrartion of an assembled stove.
4.3- Connecting to gas supply
Preparation
•
Use suitable hose that meets below standards:
Hose type
Flexible hose with clamp
Reinforced rubber hose
Metal hose
•
The hose must not exceed 1.5 metres.
•
Ensure the hose is free from stress, torsion, traction or bend.
•
The regulator and safety valve must comply with the standards in force in the country of
marketing.
•
Use with suitable gas supply only: either butane (G30) or propane (G31).
Connection
•
Ensure the appliance control knob is set to the OFF position.
•
Ensure gas regulator valve or the safety valve is set to the OFF position.
•
Attach the appliance to gas supply with the flexible hose appropriately.
•
Ensure the gas pressure is 28-30 mbar for butane gas, or 37 mbar for propane.
•
After each connection, perform leakage test in well ventilated area and away from heat
source.
Leakage test
•
Ensure the location is well ventilated and away from heat source.
•
Prepare soapy water by mixing equal portion of water and non-ammonia detergent.
•
Turn ON the gas safety valve.
•
Transfer few drops of soapy water to the connections.
•
If bubble forms, leakage are found, then turn OFF the gas safety valve and tighten the
connection. Repeat the test until no bubble is formed, or call for professional service.
4.4- Turn ON and OFF
Ignition
•
Turn ON the gas safety valve.
•
Push the control knob, then turn anticlockwise until a click is heard and the burner is lit.
•
If it is not light, turn the knob to the OFF position and repeat the ignition process.
Power adjustment
•
Turn the control knob to appropriate position for the power adjustment.
Turn OFF
Standard
XP D 36-110
XP D 36-112
NF EN 14800 + NF D 36-125
Page 11 / 19