Cartridge body:
Filter cap:
Filtering cartridge:
Hydraulic seals:
Magnet:
B (MaxT) / B (RoomT)* < 1%
Tested according to IEC 60404-5 & ASTM A977 regulations
Ball valve body:
Swivel fitting:
Compatible fluid:
Max. operating pressure:
Operating temperature:
Degree of filtration:
Noise induced (according to EN13443 and UNI 3822)
The noise induced by MG1 in the piping is 0 dB(A).
As specified in EN 13443 regulation, MG1 belongs to the I group, as well as all other products having noise levels < 20 dB(A).
Configuration 1
* Value with accessory ball valve installed code 3174.05.20
Swivel
connection:
enables to easily connect
the filter to connection G
3/4" M of the boiler.
Threaded connections G
3/4": The design choice to
make
all
the
threaded
connections of the main
body
of
the
same
dimensions, allows for an
extreme
installation
versatility.
For
further
information, please see the
"INSTALLATION"
section
on this data sheet.
Ball isolating valve: By
intercepting it, it is possible
to perform filter cleaning
operations easily.
Technical Sheet CT3070.0-EN_02
CONSTRUCTION FEATURES
(where MaxT = 130°C, RoomT = 21°C)
TECHNICAL FEATURES
DIMENSIONAL FEATURES
Configuration 2
COMPONENTS DESCRIPTION
It
Polyamide PA66 +30% FV
Polyamide PA66 +30% FV
AISI 304
EPDM PEROX
Neodymium REN35 B = 11.000 Gauss
Brass
Brass
Water, water + glycol
3 Bar
0÷90°C
800 μm
Configuration 3
Seal o-ring.
Safety drain cap: By removing it, it is possible to drain the fluid
from the main body of the filter and to perform programmed
cleaning operations, after intercepting the ball valve.
Note: It is advised that the boiler is off and the system is allowed to
cool at a room temperature before carrying out any maintenance
intervention, in order to avoid burns.
RBM
Configuration 4a / 4b
Closure filter cap.
Magnet
protection
conduit,
removable.
Stainless steel filtering mesh.
Seal o-ring.
Page 2 of 5