kurt versen
INSTALLATION INSTRUCTIONS-MultiSource
RECESSED SQUARE SHALLOW
TECHZONE PARALLEL WALL WASH
FIXTURES: J1558TZ F15, J1558TZ T9, J1558TZ T15
LED Driver
Assembly
Cast Frame
Torsion
Spring
Inner JBox Cover
Power Supply
Connector
Ground
Screw
Thermal
Protector
Junction Box
Torsion Spring
Bracket
Fig. 3 RAIL SUPPORTS
1-1/2" CHANNEL
Supports accept many types of rails. Job site scrap may be used.
Housing
Rail Supports
Bracket
Tegular Lip
Torsion Spring
Bracket
Trim Assembly
Fig. 1
Housing
LED Driver Plug
Trim Assembly
(See Trim Options)
Cast Frame
Fig. 2
1" CHANNEL
1/2" CONDUIT
CAUTION: BEFORE RELAMPING OR
REPLACING ANY ITEM
"TURN OFF POWER".
Notes
1. Make sure power is off. Building wires must be in compliance
with local codes.
2. Rails are not supplied unless ordered. They come in two sizes
26" and 52". Contact the factory. Available immediately.
3. All Electrical Wiring Must Be Made by a Licensed Electrician.
4. Fixture must be above ceiling before closing in.
Installation
1. Remove Trim assembly (Fig.1). Use the aperture Frame as a template to
mark the tile for the aperture square hole.
2. Cut tile as needed to allow it to fit snug against cast frame perpendicular
to the tegular lip.
3. Fasten rail supports to internal adjustment brackets on housing.
Insert rails by gently squeezing wings of rail supports
together to ease passage of rails. Do not squeeze too hard or
the rail supports will take a set. When pressure is released, the
rail support will lock onto rails. (See Fig. 3)
4. Remove proper knockouts from junction box and attach connectors.
5. Place fixture lip on parallel ceiling rails. Tie the rails loosely to support
members of the ceiling grid.
6. Adjust fixture and tighten rails to ceiling grid permanently.
Wiring
1. Attach conduit or flex to junction box. Make all splices.
2. Fixture must be grounded with green screw or grounding wire provided.
Installation of LED Trim Assembly (See Fig. 1&2)
1. Push in LED wire plug into two pin plug inside connector box.
2. Squeeze torsion spring and engage into slot of torsion spring bracket
then, push trim up into fixture until trim flange contacts cast frame.
Access to Junction Box: (See Fig. 2&4)
Remove trim assembly, Lift spring tab and remove inner junction box cover.
Quality Control
Every effort is made to assure that our products reach the job
in perfect condition. We welcome your comments.
Kurt Versen Company may change construction periodically without
notice as part of its program for product improvement.
Warning
Risk of fire. Do not install insulation within three inches of the fixture
sides or top in such a manner as to entrap heat.
1/2" BAR
1" BAR
701 Millennium Blvd,
Greenville, SC 29607
1.888.777.4832
®
www.kurtversen.com
1/2" - 1" ANGLE
93085884 REV A