Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

All manuals and user guides at all-guides.com
®
Professional PowerCenter
PRO5100
Owner's Manual

Publicité

Table des Matières
loading

Sommaire des Matières pour Monster Power Professional Power Center PRO5100

  • Page 1 All manuals and user guides at all-guides.com ® Professional PowerCenter ™ PRO5100 Owner’s Manual...
  • Page 2 All manuals and user guides at all-guides.com...
  • Page 3: Table Des Matières

    All manuals and user guides at all-guides.com TABLE OF CONTENTS Page Important Safety Instructions Proper Grounding and Installation ............iv A Note From The Head Monster .
  • Page 4: Important Safety Instructions

    All manuals and user guides at all-guides.com IMPORTANT SAFETY INSTRUCTIONS Please read and observe the following safety points at all times: • Read these instructions. • Keep these instructions. • Heed all warnings. • Follow all instructions. • Do not use this apparatus near water. •...
  • Page 5 All manuals and user guides at all-guides.com • Only use attachments/accessories specified by the manufacturer. • Unplug this apparatus from its power source during lightning storms or when unused for long periods of time. • Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
  • Page 6 All manuals and user guides at all-guides.com WARNING – Liquid: Avoiding Electrical Shocks Do not operate your Monster PowerCenter if liquid of any kind is spilled onto or inside the unit. Do not operate your Monster PowerCenter near rain or water that’s spilled or openly exposed (e.g., bathtub, kitchen or bathroom sink). WARNING –...
  • Page 7: Proper Grounding And Installation

    All manuals and user guides at all-guides.com PROPER GROUNDING AND INSTALLATION TIPS WARNING – Proper Grounding Your Monster PowerCenter requires a properly grounded 3-wire outlet to protect connected equipment. If your AC outlet is improperly wired (no ground or reverse polarity), the green “SYSTEM GROUNDED” LED on the front panel of the Professional PowerCenter PRO 5100 will not light up.
  • Page 8: A Note From The Head Monster

    All manuals and user guides at all-guides.com A NOTE FROM THE HEAD MONSTER THANK YOU for purchasing this Monster Power Professional PowerCenter . The PRO5100 is designed to ™ offer you the best performance and most comprehensive home theater and AV system protection available.
  • Page 9: Monster's Patented Clean Power ™ Stages

    All manuals and user guides at all-guides.com MONSTER’S PATENTED CLEAN POWER STAGES ™ Monster’s Clean Power stage numbers reflect the levels of sophistication built into our advanced filters and the greater degrees of isolation that are created between connected equipment—each successive Clean Power stage translates into an improved level of component-generated noise rejection.
  • Page 10: Monster Exclusive T2 Technology

    The Monster Power PRO5100 PowerCenter features exclusive Monster T2 technology. T2 is an active electronic microprocessor-controlled circuit that sits in front of the surge protection circuitry in select Monster Power products. T2 monitors the line, neutral and ground lines and automatically disconnects the PowerCenter from the AC power line when a long duration low-voltage sag or high-voltage swell occurs ( continuous voltage below 80Vrms or above 132Vrms).
  • Page 11: Design

    He’s designed best-selling power conditioners costing more than $3,000, and now brings his expertise to Monster Power. Richard developed Monster’s exclusive Clean Power circuitry, and several other ground breaking designs. Richard’s background and research into amplifier and capacitors led to the development of the Servo-DC feedback circuit for power amplifiers —...
  • Page 12: Pro 5100 Features

    All manuals and user guides at all-guides.com MONSTER PRO5100 POWERCENTER FEATURES PRO 5100 FRONT VIEW PRO 5100 REAR VIEW �� ��� ������� �� ��� � �� ������ ����� ��� ��� � ������� ������ �� �� ����� ����� �������� ������� ����� ��������...
  • Page 13 All manuals and user guides at all-guides.com PRO 5100 POWERCENTER FEATURES 1. “PROTECTION ON“ LED Indicator: Indicates the Monster Power Surge Protection Circuitry is functioning properly. 2. “UNSWITCHED ON“ LED Indicator: Indicates power is being supplied to the unswitched outlets.
  • Page 14 All manuals and user guides at all-guides.com 15. Ground Post: Provides a ground reference point for ungrounded components. 16. Digital Filter 1 Outlets: For digital components such as Digital Multitrack, DAT Machine, MiniDisc, Digital Signal Processor, or Recorder. This special filter circuit reduces interference from other connected components and prevents digital noise from contaminating the rest of your system.
  • Page 15 All manuals and user guides at all-guides.com special filter circuits reduce noise from the AC power line that would normally degrade PRO equipment performance. NOTE: Digital or low-current PRO equipment will not be harmed if connected to the high power outlet section. However, for best performance, we recommend using only high-current PRO components into these outlets.
  • Page 16: Hook-Up Guide

    All manuals and user guides at all-guides.com HOOK-UP GUIDE Phone Line Hookup The PowerCenter has facilities to protect a single phone line. FOR STANDARD TELEPHONE LINE PROTECTION Connect a phone cable from a telephone wall jack to the PRO 5100 IN jack (Figure 1a). Connect a second phone cable from the PRO 5100 OUT jack to the telephone (Figure 1b).
  • Page 17: Outlet Programming

    All manuals and user guides at all-guides.com Outlet Programming All outlets on the rear panel are programmable. To set up each outlet pair, use the front panel “MENU” and “SET” buttons to choose between “Switched On”, “Switched On After Delay” and “Unswitched (Always On)” independently for each outlet pair. You can change the settings, whenever you like.
  • Page 18 All manuals and user guides at all-guides.com C) Set the Outlet Pair to “Switched On After Delay”: Press “MENU” until the display shows the status of the Audio outlet pair. Press the “SET” button until the time delay changes to the required delay in seconds before the outlet pair will turn on after the “ON/OFF”...
  • Page 19: Audible Alarm Setting

    All manuals and user guides at all-guides.com Over- and Under-Voltage Audible Alarm Setting This feature enables or disables the audible alarm indicating an abnormal line voltage condition. When set to “enable”, the unit will sound an alarm when the line voltage tops 130V or drops below 100V. A) Press “MENU”...
  • Page 20: Automatic Shutdown Setting

    All manuals and user guides at all-guides.com HOOK-UP GUIDE Over- and Under-Voltage Automatic Shutdown Setting This feature enables or disables the automatic shutdown feature for abnormal line voltage. When set to ENABLE, the unit will shut itself down whenever the line voltage tops 134V or drops below 96V. Press MENU until the display shows: Press SET to toggle between ENABLE and DISABLE.
  • Page 21: Coaxial Connections

    All manuals and user guides at all-guides.com HOOK-UP GUIDE Coaxial Connections Hookup Coaxial Connections provide surge protection against damaging voltage surges and spikes on the incoming coax cable. Connect a 75-Ohm coaxial cable from a properly grounded TV/cable line, satellite dish or antenna to the "In" connection. Connect another 75-Ohm coaxial cable from the “Out”...
  • Page 22: High Power Ac Outlet Hookup

    HOOK-UP GUIDE XLR Lamp Hookup NOTE: You can purchase an optional, LED gooseneck Monster Power Flex Lamp to connect to the PRO 5100’s XLR light jack. Visit MonsterPower.com for more information on this product. Use the dimmer knob to control light intensity. To remove the Monster XLR light from the XLR Jack, press the PUSH tab, and gently pull on the metal housing of the XLR plug.
  • Page 23: Analog Ac Outlet

    All manuals and user guides at all-guides.com HOOK-UP GUIDE Analog AC Outlet Hookup Isolated Clean Power Stage 4 v.2.0 Analog Filter: Optimized to reduce noise generated by analog equipment. Isolates signals from connected digital and analog components for optimal rejection of interference. NOTE: You may want to program these outlets to be UNSWITCHED as some components perform best when powered continuously.
  • Page 24: Digital 1 & 2 Ac Outlet Hookup

    All manuals and user guides at all-guides.com HOOK-UP GUIDE Digital 1 & 2 AC Outlet Hookup Isolated Clean Power Stage 4 v.2.0 Digital Filter: Optimized to reduce noise generated by digital components. Also isolates digital signals from other connected digital, analog audio and video for maximum rejection of interference. The PRO 5100 features two isolated filters to accommodate a pair of digital sources.
  • Page 25: Troubleshooting

    All manuals and user guides at all-guides.com TROUBLESHOOTING Symptom Possible Cause Remedy The PRO 5100 is not The PowerCenter is not turned on. • Press the ON/OFF button on the PowerCenter. receiving power. • Make sure the AC power cord is plugged into a properly grounded 120V wall outlet.
  • Page 26 All manuals and user guides at all-guides.com TROUBLESHOOTING Symptom Possible Cause Remedy The PowerCenter is not providing The component is • Press the ON/OFF button on the PowerCenter. power to connected components. plugged into an outlet The components plugged into its outlets programmed as SWITCHED programmed as SWITCHED ON should ON or SWITCHED ON...
  • Page 27 All manuals and user guides at all-guides.com TROUBLESHOOTING Symptom Possible Cause Remedy The speakers The PowerCenter is sharing AC power with • Connect your PowerCenter hum or buzz. equipment that’s not properly grounded. to a dedicated outlet. The “GROUND OK” The PowerCenter is not plugged into a properly •...
  • Page 28: Dimensions

    All manuals and user guides at all-guides.com SPECIFICATIONS PRO5100 POWERCENTER Continuous Duty 120V/60Hz Electrical Rating Maximum Current Rating 15A/1800W Line-Neutral (L-N) Protection Modes Line-Ground (L-G) Neutral-Ground (N-G) Total Energy Dissipation 3145 Joules Clamping Level (TVSS Voltage) 330 Volts Clamping Response Time Less than 1 Nanosecond (<1Ns) Remote “DC In”...
  • Page 29: Frequently Asked Questions

    All manuals and user guides at all-guides.com FREQUENTLY ASKED QUESTIONS Question Answer What is the importance of With Monster PowerCenter technology, AC power is improved by noise filtering that isolates component-to-component your equipment from interference riding the AC line. Most other manufacturers just stop filtering? there, but Monster keeps going! The next crucial step of filtering occurs between connected components.
  • Page 30 All manuals and user guides at all-guides.com FREQUENTLY ASKED QUESTIONS Question Answer Will it damage a component if No. However, as mentioned, you may not realize the full performance plugged into a PowerCenter outlet potential of the component. that’s not designed for it, like putting a high-power amplifier into a Mixer/Preamplifier outlet? If my PowerCenter stops operating,...
  • Page 31 All manuals and user guides at all-guides.com LIMITED WARRANTY FOR CONSUMERS Monster, LLC, 7251 West Lake Mead Blvd, Las Vegas, NV, USA (“Monster”) extends to You this Limited Warranty. Statutory or common law may provide You with additional rights or remedies, which shall not be affected by this Limited Warranty. DEFINITIONS “Adequate Use”...
  • Page 32 All manuals and user guides at all-guides.com “Fair Market Value” (“FMV”) means the fair market value of the Connected Equipment at the time Connected Equipment Damage occurs. “Formal Warranty Claim” means a claim made in accordance with the section “Formal Warranty Claims” herein. “Maximum Coverage Amount”...
  • Page 33: General Provisions

    All manuals and user guides at all-guides.com “You” means the first individual person that purchased the Product in its original packaging from an Authorized Dealer. This Limited Warranty does not apply to persons or entities that bought the Product (i) in used or unpackaged form, (ii) for resale, lease or other commercial use, or (iii) from someone other than an Authorized Dealer.
  • Page 34 All manuals and user guides at all-guides.com SPECIFICATIONS TABLE *”Lifetime” means the lifetime of the original individual purchaser of the Product, or for as long as the original individual purchaser owns the Product, whichever is less in time. Product Warranty Period Maximum Coverage Warranty Period for Connected Model No.
  • Page 35 All manuals and user guides at all-guides.com FORMAL WARRANTY CLAIM HOW TO MAKE A CLAIM. In the event damage has occurred to Products or Connected Equipment, You must follow these instructions: (1) Call Monster within two (2) months after You discover a Product Defect (or should have discovered it, if such Product Defect was obvious);...
  • Page 36 Gort Road, Ennis, Co. Clare, Ireland 001-866-348-4171 The Monster Power Professional Reference PowerCenter PRO 5100 ™ is protected under U.S. Pat. No. 5,589,718. Other Patents Pending. “Monster” “Monster Cable” “Monster Power” “Clean Power” and “PowerCenter” are registered and unregistered trademarks of Monster, LLC.
  • Page 37 All manuals and user guides at all-guides.com ® PowerCenter Professional ™ PRO5100 Manuel de l'utilisateur MPP5100_MA...
  • Page 38 All manuals and user guides at all-guides.com...
  • Page 39 All manuals and user guides at all-guides.com TABLE DES MATIÈRES Page Importantes instructions de sécurité ........................i Mise à la terre et installation adéquates ......................iv Note de la direction de Monster.......................... 1 Étages brevetés Clean Power de Monster ......................2 ™ Technologie T2 exclusive de Monster.........................
  • Page 40: Importantes Instructions De Sécurité

    All manuals and user guides at all-guides.com IMPORTANTES INSTRUCTIONS DE SÉCURITÉ Veuillez lire et observer les points de sécurité suivants en tout temps : • Lisez ces instructions. • Conservez ces instructions. • Respectez les mises en gardes. • Conformez-vous à ces instructions. •...
  • Page 41 All manuals and user guides at all-guides.com • Débranchez cet appareil de sa source d’alimentation durant les orages électriques ou lorsqu’il est inutilisé pour de longues périodes. • Pour toute réparation, consultez un personnel de service qualifié. Des réparations sont requises lorsque l’appareil a été endommagé...
  • Page 42 All manuals and user guides at all-guides.com MISE EN GARDE – Liquides : Éviter les chocs électriques N’utilisez pas votre PowerCenter de Monster si un liquide a été renversé sur ou à l’intérieur de l’appareil. N’utilisez pas votre PowerCenter de Monster près d’un endroit où l’on retrouve de l’eau ou de la pluie (par exemple un bain, une cuisine ou un évier). MISE EN GARDE - Sécurité...
  • Page 43: Mise À La Terre Et Installation Adéquates

    All manuals and user guides at all-guides.com ASTUCES MISE À LA TERRE ET INSTALLATION ADÉQUATES MISE EN GARDE – Mise à la terre adéquate Votre PowerCenter de Monster requiert une prise triphasée adéquatement mise à la terre pour protéger l’équipement connecté.
  • Page 44: Note De La Direction De Monster

    All manuals and user guides at all-guides.com NOTE DE LA DIRECTION DE MONSTER MERCI de vous être procuré ce PowerCenter Professional de Monster Power . Le PRO5100 est ™ conçu pour vous offrir la meilleure performance et le système de protection de cinéma maison et de protection audio/vidéo le plus complet sur le marché.
  • Page 45: Étages Brevetés Clean Power ™ De Monster

    All manuals and user guides at all-guides.com ÉTAGES BREVETÉS CLEAN POWER DE MONSTER ™ Le nombre d’étages du Clean Power de Monster reflète le niveau de sophistication intégré dans nos filtres avancés et le degré plus élevé d’isolation qui a été créé entre l’équipement branché - chaque étage successif du Clean Power se traduit par un niveau amélioré...
  • Page 46: Technologie T2 ™ Exclusive De Monster

    électronique logé à l’avant du circuit de protection contre les surtensions dans tous les produits Monster Power. La technologie T2 contrôle les lignes de phase, du neutre et de la borne terre et déconnecte automatiquement l’alimentation du PowerCenter dans le cas d’une chute de tension ou d’une hausse de tension sur une longue durée (tension continue en dessous de 80 Vrms ou au-dessus de 132 Vrms).
  • Page 47: Les Cerveaux Derrière La Conception Du Powercenter

    Monster dans plus de 80 pays. Monster Power est pour lui la réalisation d’une vision longuement entretenue d’offrir des solutions d’alimentation abordables qui délivrent le meilleur son et la meilleure image possibles.
  • Page 48: Caractéristiques Du Powercenter Professional ™ Pro 5100 De Monster

    All manuals and user guides at all-guides.com CARACTÉRISTIQUES DU POWERCENTER PRO 5100 DE MONSTER PRO 5100 VUE AVANT PRO 5100 VUE ARRIÈRE �� ��� ������� �� ��� � �� ������ ����� ��� ��� � ������� ������ �� �� ����� ����� ��������...
  • Page 49 All manuals and user guides at all-guides.com CARACTÉRISTIQUES DU POWERCENTER PRO 5100 1. “Témoin de fonctionnement du mode de PROTECTION“ : Indique que le circuit de protection de surtension Monster Power fonctionne adéquatement. 2. “Témoin de fonctionnement du mode non commuté UNSWITCHED” : Indique si les prises d’alimentation non commutées de l’appareil sont mises sous tension.
  • Page 50 All manuals and user guides at all-guides.com 11. Bouton MENU : Appuyez pour démarrer le mode de programmation. 12. Bouton SET : Appuyez pour valider les paramètres ou les options sélectionnées par le bouton MENU. 13. Bouton du gradateur DIMMER : Contrôle l’éclairage de l’afficheur alpha-numérique. 14.
  • Page 51 All manuals and user guides at all-guides.com 20. Sorties du filtre à courant élevé 1 : Optimisés pour les composants analogiques à courant élevé comme les caissons d’extrême-grave ou l’amplificateur principal, les circuits spéciaux du filtre réduisent le bruit provenant de la ligne d’alimentation c.a.
  • Page 52: Guide De Raccordement

    All manuals and user guides at all-guides.com GUIDE DE RACCORDEMENT Raccordement de ligne téléphonique Le PowerCenter a la possibilité de protéger une simple ligne téléphonique. POUR UNE PROTECTION DE LIGNE TÉLÉPHONIQUE STANDARD Branchez un câble téléphonique à partir d’une prise téléphonique murale à la prise PRO 5100 IN (Figure 1a). Branchez un second câble téléphonique à...
  • Page 53 All manuals and user guides at all-guides.com Programmation de sortie Toutes les sorties du panneau arrière sont programmables. Pour régler chaque paire de prise, utilisez les boutons MENU et SET du panneau avant pour choisir entre les modes de commutation SWITCHED ON, commutation avec retard d’allumage SWITCHED ON AFTER DELAY et non commuté...
  • Page 54 All manuals and user guides at all-guides.com C) Régler la paire de prises en mode de commutation avec retard d’allumage SWITCHED ON AFTER DELAY : Appuyez sur MENU jusqu’à ce que l’afficheur indique le statut de la paire de prises audio. Appuyez sur le bouton “SET”...
  • Page 55: Réglage De L'alarme Sonore

    All manuals and user guides at all-guides.com Réglage de l’alarme sonore de surtension et de sous-tension Cette fonction active ou désactive l’alarme sonore indicant une condition d’alimentation anormale sur la ligne. Lorsque l’alarme est en mode activé ENABLE, l’alarme sonnera lorsque la tension d’alimentation dépasse 130V ou tombe sous 100V.
  • Page 56: Guide De Raccordement

    All manuals and user guides at all-guides.com GUIDE DE RACCORDEMENT Réglage de l’extinction automatique lors de surtension et de sous-tension Cette fonction active ou désactive l’extinction automatique lors d’une condition d’alimentation anormale sur la ligne. Lorsque la fonction est en mode activé ENABLE, l’appareil s’éteindra automatiquement lorsque la tension d’alimentation dépasse 134V ou tombe sous 96V.
  • Page 57: Connexions Coaxiales

    All manuals and user guides at all-guides.com GUIDE DE RACCORDEMENT Raccordement des connexions coaxiales Les connexions coaxiales offrent une protection contre les surtensions dommageables et les pics de tension entrant dans le câble coaxial. Reliez un câble coaxial de 75 ohms à partir d’une ligne de câble/télé, d’une antenne ou d’une antenne satellite adéquatement mise à...
  • Page 58 All manuals and user guides at all-guides.com GUIDE DE RACCORDEMENT Raccordement de la lampe XLR REMARQUE : Vous pouvez vous procurer une lampe flexible à col de cygne LED en option pour brancher à la prise de la lampe XLR du PRO 5100. Visite MonsterPower.com pour de plus amples informations sur ce produit. Utilisez le bouton du régulateur pour contrôler l’intensité...
  • Page 59 All manuals and user guides at all-guides.com GUIDE DE RACCORDEMENT Raccordement de la sortie c.a. analogique Filtre analogue isolé Clean Power 4 étages v.2.0 : Optimisé pour réduire le bruit généré par l’équipement analogique. Isole les signaux des composants branchés numériques et analogiques pour une élimination optimale des interférences. REMARQUE : Vous désirerez peut-être programmer ces sorties pour qu’elles soient non commutées UNSWITCHED car certains composants se comportent mieux lorsqu’ils sont alimentés en continu.
  • Page 60 All manuals and user guides at all-guides.com GUIDE DE RACCORDEMENT Raccordement des sorties c.a. 1 et 2 numériques Filtre numérique isolé Clean Power 4 étages v.2.0 : Optimisé pour réduire le bruit généré par l’équipement analogique. Isole également les signaux numériques des autres dispositifs numériques, audio analogiques et vidéo pour une élimination maximale des interférences.
  • Page 61: Dépannage

    All manuals and user guides at all-guides.com DÉPANNAGE Symptôme Cause possible Solution Le PRO 5100 ne reçoit Le PowerCenter n’est pas allumé. • Appuyez sur le bouton ON/OFF du PowerCenter. aucune alimentation. • Assurez-vous que le cordon d’alimentation c.a. est branché dans une prise murale de 120 volts adéquatement mise à...
  • Page 62 All manuals and user guides at all-guides.com DÉPANNAGE Symptôme Cause possible Solution Le PowerCenter ne fournit Le composant est branché dans une • Appuyez sur le bouton ON/OFF du aucune alimentation aux sortie programmée au mode commuté PowerCenter. Les composants branchés dans composants branchés.
  • Page 63 All manuals and user guides at all-guides.com DÉPANNAGE Symptôme Cause possible Solution Les haut-parleurs Le PowerCenter partage son alimentation c.a. • Connectez votre PowerCenter bourdonnent avec un appareil qui n’est pas correctement mis à une prise murale dédiée. ou crépitent. à...
  • Page 64: Contrôle De L'alimentation D'entrée C.c. "Dc In" À Distance

    All manuals and user guides at all-guides.com SPÉCIFICATIONS PRO5100 POWERCENTER Catégorisation électrique 120V/60Hz tâche continue Courant maximum 15A/1800W Ligne-Neutre (L-N) Modes de protection Ligne-Terre (L-G) Neutre-Terre (N-G) Dissipation d’énergie totale 3145 Joules Niveau de blocage (tension de suppression 330 Volts des surtensions transitoires) Temps de réponse de blocage Moins de 1 nanoseconde (<1ns)
  • Page 65: Foire Aux Questions

    All manuals and user guides at all-guides.com FOIRE AUX QUESTIONS Question Réponse Quelle est l’importance Grâce à la technologie du PowerCenter de Monster, l’alimentation c.a. est améliorée par le du filtrage composant-à- filtrage du bruit qui isole votre équipement de l’interférence parcourant les lignes c.a. La plupart composant ? des autres fabricants s’arrêtent ici mais Monster va plus loin ! L’étape importante suivante de filtrage se produit entre les composants branchés.
  • Page 66 All manuals and user guides at all-guides.com FOIRE AUX QUESTIONS Question Réponse Est-ce que cela endommagerait Non. Toutefois, tel que mentionné, vous pourriez ne pas réaliser le plein potentiel un composant que de le brancher de performance du composant. dans une prise PowerCenter qui n’est pas destinée à...
  • Page 67: Garantie Limitée Aux Consommateurs

    All manuals and user guides at all-guides.com GARANTIE LIMITÉE AUX CONSOMMATEURS Monster, LLC, 7251 West Lake Mead Blvd, Las Vegas, NV, USA (« Monster ») vous offre cette Garantie limitée. Il se peut que la législation en vigueur ou la Common Law de votre pays vous octroie des droits ou recours additionnels qui ne seront pas affectés par cette Garantie limitée.
  • Page 68 All manuals and user guides at all-guides.com Par « Dommages subis par le matériel connecté », il faut entendre les dommages matériels qu’aurait subi le Matériel connecté en raison d’un Défaut du produit (i) suite à une surtension passagère de l’alimentation c.a. ou de la ligne de câble ou de téléphone, ou encore à...
  • Page 69: Étendue De Cette Garantie Limitée

    All manuals and user guides at all-guides.com Par « Période de garantie », il faut entendre le délai au cours duquel Monster doit recevoir votre Réclamation officielle au titre de la garantie. Les différentes Périodes de garantie assorties aux Défauts de produit et aux dommages du Matériel connecté...
  • Page 70: Provisions Générales

    All manuals and user guides at all-guides.com de vous une Réclamation officielle au titre de la garantie émanant avant la fin de la Période de garantie concernant les Dommages subis par le Matériel connecté applicables au Produit concerné. Si les conditions mentionnées dans la phrase précédente sont réunies, Monster vous offrira l’un des recours suivants tout en se réservant, à...
  • Page 71 All manuals and user guides at all-guides.com pas vos droits légaux. TABLEAU DES SPÉCIFICATIONS Période de garantie - Numéro de modèle Période de Dommages subis Montant maximum couvert de Produit garantie - Produits par le Matériel connecté Le matériel connecté Le matériel connecté...
  • Page 72: Réclamation Officielle Au Titre De La Garantie

    All manuals and user guides at all-guides.com RÉCLAMATION OFFICIELLE AU TITRE DE LA GARANTIE COMMENT EFFECTUER VOTRE RÉCLAMATION. Dans l’éventualité où les Produits ou le Matériel connecté seraient endommagés, conformez-vous à ces instructions : (1) (1) Contactez Monster dans les deux (2) mois suivant Votre découverte d’un Défaut du Produit (ou que vous auriez dû...
  • Page 73 Le PowerCenter Professional de Monster PRO 5100 ™ de référence est protégé selon le numéro de brevet 5,589,718. D’autres brevets sont en attente. “Monster” “Monster Cable” “Monster Power” “Clean Power” et “PowerCenter” sont des marques de commerce déposées ou non déposées de Monster, LLC.
  • Page 74 All manuals and user guides at all-guides.com...

Table des Matières