nutribullet
cup
®
assembly.
1
Add ingredients* to the
nutribullet
Cup.
®
2
Place the Extractor Blade
onto the nutribullet
and twist until it is tightly
sealed.
3
Turn the nutribullet
®
upside down and place
it onto the Motor Base.
Gently push and twist,
60-second auto blending
cycle will be activated.
The blue light and unit will
shut off once auto-mode is
completed.
4
Unlock the assembly
by gently pushing and
untwisting the cup
counterclockwise.
5
Once the Extractor Blade
stops completely, remove
the nutribullet
Cup from
®
the Motor Base. Enjoy!
CAUTION: Do not run the Motor Base in excess of 1
minute per interval. Do not run the Motor Base for more
than three 1-minute intervals without allowing it to cool
for 2-3 minutes after the third extraction. Running the
motor for more than 1 minute consecutively in any interval
may warm the ingredients and pressurize the nutribullet
Cup. Friction from the rotating Extractor Blade when
extracting can cause ingredients to heat and generate
internal pressure in the sealed vessel. If the vessel is warm
to touch, allow to cool before carefully opening pointed
away from your body.
8
Pulse mode.
Because the nutribullet's motor is so powerful, it
emulsifies the ingredients when you extract. That is
why when you want to make foods such as chunky
salsa, or coarse chopped onions, Pulse Mode is
key. Pulsing takes a tiny bit of getting used to, but
once you get a feel for it, you'll be a Pro in no time!
1
To Pulse, push and twist
the nutribullet
the Power Base. Press
the Pulse Button within
5 seconds of blending,
Cup
®
which will pause current
blending cycle to activate
pulse
button
manual pulse mode.
PULSE
2
The Pulse Button will flash
BLUE indicating that it's in
Cup
Pulse Mode.
NOTE: Pulse Mode is active
for 1 minute and then times
out. If the Vessel is still in
PULSE
the ON position, nothing will
happen. The Vessel must be
rotated counter-clockwise
to OFF position and then
normal function may be
resumed.
3
Press and hold the Pulse
Button to make the Blades
turn. Release the Pulse
Button to stop the Blades.
Let the Blades come to a
complete stop after each
Pulse and press the Pulse
PULSE
Button again until you get
the consistency you desire.
CAUTION: Do not run the Motor Base in excess of 1
minute per interval. Do not run the Motor Base for more
than three 1-minute intervals without allowing it to cool for
2-3 minutes after the third extraction. Running the motor
for more than 1 minute consecutively in any interval may
warm the ingredients and pressurize the nutribullet
Cup. Friction from the rotating Extractor Blade when
extracting can cause ingredients to heat and generate
internal pressure in the sealed vessel. If the vessel is warm
to touch, allow to cool before carefully opening pointed
away from your body.
®
Care & maintenance.
Cleaning the nutribullet
pieces (except for the Motor Base and Extractor Blade)
on the
TOP RACK
of the dishwasher or hand wash with
warm soapy water and rinse.
Here's how to clean the
nutribullet
Cup onto
®
STEP 1:
The most important thing — ALWAYS UNPLUG the
Motor Base from the power supply outlet when it is
left unattended, before assembling, disassembling,
changing accessories or approaching parts that
move in use, or when cleaning.
handle the appliance until all parts have stopped
moving!
STEP 2:
Remove the nutribullet
from the Motor Base.
STEP 3:
Clean the individual components (Motor Base, Extractor
Blades, nutribullet
MOTOR BASE:
• For the most part, the Motor Base doesn't really get
dirty, but if you neglect to twist the Extractor Blade
on to the nutribullet
out and get into the Motor Base and stick to the
activator buttons.
• To avoid risk of injury,
utensils to clean the white actuator Tabs while the
nutribullet
is plugged in.
®
• Do not remove the rubber or plastic liners inside
the Motor Base.
• Use a sponge or dish cloth dampened with warm
soapy water to wipe down the inside and outside of
the Motor Base until clean.
• Pay particular attention to the white actuator tabs
on the inside of the Motor Base to loosen any sticky
debris from drips and spills. If necessary, you may
use a small brush to scrub the area to ensure it is
kept clean.
®
WARNING:
Never submerge the Motor Base in
water.
EXTRACTOR BLADE:
DO NOT REMOVE THE GASKET
•
permanently damage the Extractor Blade and
cause leakage. If after washing as indicated
above additional disinfecting is desired, you
may rinse with a 10% vinegar/water solution
or with lemon juice. If, over time, the gasket
becomes loose or damaged, you may order a
is easy, simply place any of the
new Extractor Blade at nutribullet.com or contact
®
Customer Service.
• Dry the Extractor Blade completely. It is helpful
to turn the Extractor Blade on its side in your dish
drainer to ensure
Blade are completely dried.
:
®
NUTRIBULLET
• These items are all
We recommend rinsing them and giving them a
quick brush with a dish brush to remove any dried
debris before washing them in the dishwasher.
NEVER
nutribullet
Do not attempt to
• Regularly check the 3 tabs on the side of the
nutribullet
rounding). If damaged, replace immediately to
prevent possible personal injury.
Cup/Extractor Blade assembly
®
• NEVER USE A CUP WITH A BROKEN, DAMAGED,
OR MISSING TAB AS DOING SO MAY CAUSE THE
CUP AND MOTOR BASE TO SEPARATE EXPOSING
THE BLADE ASSEMBLY!
Cups) as follows:
®
STUBBORN CLEAN UP:
• If ingredients dry inside the nutribullet
make your cleanup a snap by filling the cup about
2/3 full with room temperature (21°C/70°F or less)
Cup tightly, liquids can leak
®
water and screw on the Extractor Blade. Place the
nutribullet
nutribullet
NEVER
use your hands or
This will loosen the stuck ingredients, and with a
light scrub and rinse, you'll be all finished.
as this will
BOTH SIDES
of the Extractor
CUPS & TO-GO LIDS:
®
TOP RACK
dishwasher safe.
use the sanitize cycle to wash the
Cups as this may warp the plastic.
®
Cups (cracking, crazing, breakage or
®
Cup,
®
Cup/Extractor Blade assembly on the
®
Motor Base for about 20-30 seconds.
®
9