Typical installation 2:
Back locking screw
Bearing sleeve nut
Door frame
2mm allen key
Note:Sizes with (A) denote additional 1mm clearance
Sizes with (B) denote additional 2mm clearance
Scribe for the cut-out area, follows wiring instruction and position the VX
1982 35.5 into the scribe area, use allen key to turn clockwise the back
locking screw mount up the unit tight against the door frame (refer to
installation diagram). The top piece sleeve nut must be screw tight and glue
and must not pop up higher than the flat armature surface.
Important safety precaution
Secure firmly the VX1982 35.5 mechanical electro magnet on the door
frame. The provided screws must be used in accordance with the frame or
support material.
4.2
Drill holes,
5.5
9.5
4places
2mm allen key
Instruction
3
Maintenance
Contacting surface of the Mechanical Electro Magnet and Armature plate must
be kept free of contaminating materials. Surfaces should be cleaned
periodically with a non-abrasive cleaner. Do not spray the Mechanical Electro
Magnet or Armature plate surface with any lacquer chemicals. This will cause
serious problems with the release of the Mechanical Electro Magnet and its
Armature plate that would result to serious safety problems.
Trouble Shooting
PROBLEM
POSSIBLE CAUSE
No DC voltage to lock.
Door will not
Wrong wire connection.
lock
Bearing sleeve nut rise
higher than magnet flat
surface.
Bad physical contact
Holding Force
between armature plate
reduced
and magnet surface.
There is a delay
The power switch-off is
in door release
disturbed by the power
when power off.
supply stabilisation.
SOLUTION
Check power and loose
wiring
Check wiring, refer to wiring
instruction.
Screw in the bearing sleeve
nut at level with surface with
the provided security screw.
Make sure than surface
contact is cleaned and well
aligned with the armature
plate
The power cut must be done
between the PSU and lock.
Not at the AC input of the
PSU.
4