5100 SERIES
PRODUCT FEATURES
Forced air electric unit heater available in 208,
240/208, 227, 480, 550 or 600 volt as standard.
Ten standard heating capacities of 3.3 KW/11,260
BTUH thru 50.0 KW/170, 600 BTUH.
208 and 240/208 volt models are single phase field
convertible to three phase on 3.3 thru 10.0 KW
Models. (Single phase only available on 3.3, 5.0, 7.5
and 10 KW 277 volt models.
Specially designed inlet louver allows the fan to pull
cool air evenly across the high mass all-steel element.
Outward drawn venturi and adjustable louver
assembly further directs the outlet air in a uniform
pattern to meet specific air pattern requirements in
either the horizontal or vertical mounting position.
Optional wall/ceiling or vertical mounting brackets (as
required).
IMPORTANT: OWNER SHOULD RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE
Horizontal or Vertical Mounting
Industrial / Commercial
NOT FOR RESIDENTIAL USE
ATTENTION:
Read
carefully
attempting to install, operate or service
the TaskMaster Unit Heater. Retain these
installation instructions for future use.
Unit Heater
before
Four position weld nuts supplied in case top and back
for field mounting by threaded rods or eye bolt with
chain. (Hardware supplied by others).
Optional radial or anemostat diffusers lending air
pattern versatility when mounted vertically.
Modular control kits for field installation. Disconnect
switch, thermostat, summer fan switch, heat recovery
thermostat. All kits with spade terminals (Except
disconnect switch).
Single point terminal board wiring of integral control
kits.
24 volt low voltage control circuit standard on all
contactor and transformer models.
Roomy control box with access door locked into
position by two (2) 1/4 turn fasteners for ease of
installation.
1 of 20
INSTALLATION
INSTRUCTIONS
& PARTS LIST
ECO 1-7874
REV. 10/22
FORM: 9632

Publicité

Table des Matières
loading

Sommaire des Matières pour TPI TASKMASTER 5100 Serie

  • Page 1 TASKMASTER INSTALLATION INSTRUCTIONS 5100 SERIES & PARTS LIST Horizontal or Vertical Mounting Industrial / Commercial Unit Heater NOT FOR RESIDENTIAL USE ATTENTION: Read carefully before attempting to install, operate or service the TaskMaster Unit Heater. Retain these installation instructions for future use. PRODUCT FEATURES •...
  • Page 2: Important Instructions

    IMPORTANT INSTRUCTIONS When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electrical shock, and injury to persons, including the following: 1. Read all instructions before using this heater. 2. CAUTION: High temperatures. Keep cords and all other combustible material, such as furniture, papers, clothes and curtains away from the heater.
  • Page 3 PROPER LOCATION INSTRUCTIONS GENERAL SAFETY INFORMATION / CAUTION: Once the total heating load is calculated, the quantity and Follow all local electrical and safety codes, as well as the capacity of the unit heaters must be determined. because a National Electrical Code (NEC) and the Occupational Safety large number of low-capacity heaters provides more uniform and Health Act (OSHA).
  • Page 4: Principles Of Operation

    PRINCIPLES OF OPERATION Upon a call for heat from the floor level or unit mounted When the unit mounted stratification thermostat closes on a optional accessory thermostat, the unit fan motor and temperature rise and at the same time the floor thermostat heating elements shall be energized and remain ON until calls for heat, the motor shall be energized immediately temperature reaches setting of thermostat;...
  • Page 5: Dimensions (Inches)

    INSTALLATION INSTRUCTIONS TASKMASTER -- 5100 SERIES UNIT HEATER ATTENTION: READ INSTRUCTION CAREFULLY Heaters may be mounted in the horizontal or vertical air discharge All electric unit heaters are shipped fully assembled. Installation includes configuration using factory optional supplied accessory mounting equipment hanging the unit, mounting the built-in and remote accessories, wiring of or using special hardware facilities supplied by others.
  • Page 6 INSTALLATION INSTRUCTIONS TASKMASTER -- 5100 SERIES UNIT HEATER (part 2) HORIZONTAL -- AIR DISCHARGE MOUNTING SHOWN IN: FIGURE 7 SHOWN IN: FIGURE 5 & 6 Attach short angle brackets “A” to back of heater with four 5/16 X 18 Swivel hanger brackets may be used to suspend unit heaters from either capscrews “B”, lockwashers “F”.
  • Page 7 5100 SERIES UNIT HEATER ELECTRICAL DATA (Table 2) AMPS BRANCH SUPPLY SIZE Catalog BTU/HR HEATER/MOTOR HEATER CONTROL PROTECTION SIZE 60 Number (000) VOLTAGE PHASE VOLTAGE PHASE SIZE (A) AWG. ** F1F5103 11.2 15.9 5103NF1F F2F5103 15.9 11.2 5103NF2F HF1B5103 3.3/2.5 11.2/8.5 240/208 240/208...
  • Page 8 5100 SERIES UNIT HEATER ELECTRICAL DATA (Table 2) CON’T. AMPS BRANCH SUPPLY SIZE Catalog BTU/HR HEATER/MOTOR HEATER CONTROL PROTECTION SIZE 60 Number (000) VOLTAGE PHASE VOLTAGE PHASE SIZE (A) AWG. ** F3F5130CA1 30.0 102.4 83.4 5130CA1LF3F 30.0 102.4 83.4 HF3B5130CA1 30.0/22.5 102.4/76.8 208/240...
  • Page 9 5100 SERIES UNIT HEATER AIR DELIVERY DATA FAN MOTOR DATA TEMPERATURE MAX. MTG. CFM at FRM at AIR THROW WEIGHT RISE MOTOR RPM OUTLET OUTLET HORIZONTAL LBS. HORIZONTAL VERTICAL 1030 1/125 1550 12 Ft. 1030 1/125 1550 12 Ft. 1030 1/125 1550 12 Ft.
  • Page 10: Lubrication

    5100 SERIES UNIT HEATER TROUBLE SHOOTING GUIDE SYMPTOM POSSIBLE CAUSE(S) CORRECTIVE ACTION Thermostat calls for heat, but heater does not Open (blown) fuse Replace fuses, check for cause. (see function. Replacement Parts List for fuse size) INCORRECT WIRING CHECK WIRING CONNECTIONS Thermal cut-out open, de-energizing heater element and control circuit.
  • Page 11 5100 SERIES UNIT HEATER WIRING DIAGRAM SCHEDULE MODEL CODE DIAGRAM NO. MODEL CODE SIZE AND CONTROL SYSTEM PREFIX WD5101 F1F-G1G-HF1B 5103 5105 WD5102 FIF-GIG-HF1B 5103C3 5105C3 5107C3 5110C3 WD5104 F1F-G1G 5103CA1 5105CA1 5107CA1 5110CA1 WD5106 F2F-HF2B 5103 5105 WD5107 F2F-HF2B 5103C3 5105C3 WD5109...
  • Page 12 ELEMENT ASSEMBLY AUTO RESET MOTOR FAN BLADE FAN OVERRIDE LOUVER FUSE BLOCK FUSES CAPACITOR TERMINAL BOARD CONTACTOR TRANSFORMER TERMINAL BLOCK ECO 1-7874 12 of 20 REV. 10/22 FORM: 9632...
  • Page 13 5100 SERIES UNIT HEATER PARTS LIST - CATALOG NUMBERS POWER HEATER ELEMENT AUTOMATIC MOTOR XMFR CONTACTOR TERMINAL MODEL ASSEMBLY RESET OVERRIDE BLOCK F1F5103N 56562-012 60715-001 57640-006 28163-005 56815-001 5103NF1F 56562-012 60715-001 57640-006 28163-005 56815-001 F25103N 56562-012 60715-011 57640-006 28163-005 56815-001 5103NF2F 56562-012 60715-011...
  • Page 14 5100 SERIES UNIT HEATER PARTS LIST - CATALOG NUMBERS POWER ELEMENT AUTO S.D. FUSE S.D. FUSE CONTACTOR HEATER MODEL MOTOR XMFR TERMINAL ASSEMBLY RESET OVERRIDE 6 RQD 2 RQD 2 RQD BLOCK F3F5125CA1L 56943-001 56954-017 57640-005 56811-002 60719-009 50836-012 41280-002 50378-025 57097-001 57112-001...
  • Page 15 5100 SERIES UNIT HEATER PARTS LIST - CATALOG NUMBERS - 600 VOLT MODELS U3H5105CA4N U3H5107CA4N U3H5110CA4N U3H5115CA4N U3H5120CA4N 56825-002 56825-002 MOTOR 56592-017 56823-012 56823-012 56954-032 56954-035 ELEMENT ASS’Y. 56954-029 56954-030 56954-031 AUTO RESET LIMIT 57640-003 57640-003 57640-003 57640-004 57640-004 56811-001 56811-003 FAN OVERRIDE 56811-001...
  • Page 16: Caracteristiques

    TASKMASTER INSTALLATION INSTRUCTIONS 5100 SERIES & PARTS LIST Montage horizontal ou vertical radiateur industriel et commercial ATTENTION: Lisez les instructions soigneusement avant de commencer l’installation, la mise en marche ou l’entretien du radiateur taskmaster. Gardez ces instructions pour utilisation ulterieure. CARACTERISTIQUES •...
  • Page 17: Instructions D'endroit Nécessaires

    INSTRUCTIONS D'ENDROIT NÉCESSAIRES Général SAFETY INFORMATION / PRUDENCE : Dès que la charge totale de chauffage est calculée, la Suivez tout l'habitant d'origine électrique et les codes de quantité et la capacité des chauffages d'unité doivent être sécurité, aussi bien que le Code Électrique national (NEC) déterminés.
  • Page 18 PRINCIPES D'OPÉRATION Quand l'unité est montée des fins de thermostat de stratification sur Sur une demande de la chaleur du niveau d'étage ou de l'unité une augmentation de température et en même temps le thermostat est monté le thermostat auxiliaire optionnel, le moteur de fan d'étage demande la chaleur, le moteur sera stimulé...
  • Page 19 INSTRUCTIONS D'INSTALLATION TYRAN - 5100 CHAUFFAGE D'UNITÉ DE SÉRIE ATTENTION : LISEZ L'INSTRUCTION SOIGNEUSEMENT Les chauffages peuvent être montés dans la configuration de renvoi Tous les chauffages d'unité électriques sont expédiés complètement aérienne horizontale ou verticale en utilisant l'équipement montant rassemblés.
  • Page 20 INSTRUCTIONS D'INSTALLATION LE TYRAN - 5100 CHAUFFAGE D'UNITÉ DE SÉRIE (la partie 2) HORIZONTAL - LE RENVOI AÉRIEN MONTANT VERTICAL - LE RENVOI AÉRIEN MONTANT MONTRÉ DANS : LA FIGURE 5 ET 6 MONTRÉ DANS : LA FIGURE 7 Attachez des crochets courts “A” au revers de chauffage avec Pivotez les parenthèses de cintre peuvent être utilisées pour quatre 5/16 X 18 capscrews “B”, lockwashers “F”.

Table des Matières