Flow gauge
The adjustment of the volume flow of the heat transfer
fluid happens via limiting of the pumping rotation speed,
which can be adjusted in the solar controller.The current
flow can be seen on the flow indicator. The display range
lies between 1 and 13l/min.
(Additional information can be found in the manual of the
solar controller SKSC2HE).
Chok [B] for setting
the volume flow
Read off the volume
flow from the upper
edge of the float
Sensor for flow and temperature
measurement (optional)
For the heat quantity measurement via the controller
SKSC2HE a sensor for flow and temperature measure-
ment can be used optionally.
The adjustment of the volume flow of the heat transfer
fluid happens via limiting the pumping rotation speed,
which can be adjusted in the solar controller. The current
flow can be read on the controller´s display.
(Additional information can be found in the manual of the
solar controller SKSC2HE)