with directional control and the rest are closable and are used in conjunction with the
appropriate sized plastic Y-branches. The heater is made from corrosion resistant materials
and sealed against the ingress of water, however suitable provision should be made to protect
the heater from direct road spray and debris.
Technical Specifications
Model: SH2211 Maximum dimensions: Height: 230mm, Width: 157mm, length:
430mm
Weight Under-floor Installation 7.7kg
Gas: Butane 28-30mbar - CAT I3+ (28-30/37), Butane/Propane 30mbar - CAT I3B/P
(30)
Propane 37mbar - CAT I3p (37)
Gas Consumption (M) 150g/h
Classification of Heater: Type: C53 (Fanned) Normal Installation
C13 Vehicle In Motion Installation
Nominal Heat Input: Gas 2.0Kw
Battery Supply
Nominal voltage: 12V d.c.
Operating range: 10.0V d.c. min. to 15V d.c. max.
Maximum current d.c. gas operation: 1.7 Amps (0.01Amps on standby)
Dry Storage Temperature: -20°C to 70°C
Hot Air Duct Diameter: 60mm ID
Flue Diameter: 22mm ID
Maximum Exhaust Flue Length: 2m
Minimum Exhaust Flue Length: 0.75m
Maximum Combustion Air Flue Length: 2m
Minimum Combustion Air Flue Length: 1.0m
SERIAL-Kombi, 80 route de Chambéry, 38420 Le Versoud France, 04 76 77 59 18
INFO_TEC_SERIAL-Kombi_HS2211_FR_GB V1.2 Janvier 2015
www.serial-kombi.com contact@serial-kombi.com