Max. temperature pumped fl uid: 40 C°
Max. immersion depth: 20 metre.
The minimum pumping level is: 10 cm. above the pump body.
PH of the liquid to be pumped: 6 - 10
Power and other specifi ca on: See the electropump plate.

HANDLING

Check that there are no breakages or severe dents in the packing; if there are, point this out
immediately to the person who delivers the material. A er removing the electropump from the
package, check that it has not suff ered any damage during transport; if damage is found, inform the
dealer within 8 days of delivery.
The electropump is packed in a cardboard box for transport; as its total weight and bulk are not
excessive, transport presents no problems.
The electropumps must never be carried, li ed or made to operate hanging from their power cable.
If the power cable is damaged in any way it must be replaced and not repaired.
Qualifi ed personnel must also be employed for all electrical repairs which, if badly carried out, could
cause damage and accidents.
SUB ZERO TEMPERATURE
he electropump can withstand sub-zero temperatures as long as it is opera ng or completely
T
immersed in the water.
The impeller may freeze if the eletropump is removed from the water, and therefore exposed to

sub-zero temperatures.

In this case, immerse the electropump in the water and let the ice melt before star ng.
Never use a fl ame to not ruin the gasket and plas c parts of the pump.

CLEANING

If the electropump has been used in a liquid with solid par cles, run it in clean water for a few
minutes.
Otherwise mud, cement and similar impuri es may dry up, blocking the seals and stopping the
electropump from working.

STORAGE

f the electropump will not be used for a long me:
I
store it in a dry place;
put it in ver cal posi on and check it is stable and fi rm.
During a storage period, we suggest to make the impeller roll, by hands, at least every 2 months, in
order to avoid the mechanical seals s ck.
If the pump has been stopped for more than 6 months, this rota on movement becomes
necessary.

MAINTENANCE WORK

TYPE ELECTROPUMP
TOP TECNO / HYDRA / ENERGY 1 2
TOP TECNO / HYDRA / ENERGY 3 4 5 6
TOP TECNO / HYDRA / ENERGY 7 75 8 85 10 11
TOP PROFESSIONAL T H E
TECNO / HYDRA / ENERGY 9
AFPUMPS S.r.l.
www.afpumps.com
Tel. +39 0429 778295
EN 3
Oil motor
160 ML
350 ML
500 ML
500 ML
600 ML
info@afpumps.com

Publicité

Table des Matières
loading

Table des Matières