AUTO WATER LEVELER
CMP 25504-10
-000
X
BACKFLOW
It is recommended to install the Water Leveler
with a control to prevent reverse flow such as
an anti-siphon or a double-check valve.
OVERFLOW
An opening for overflow protection is built
into the Water Leveler. To install the unit without
the overflow protection, seal the opening with the
1/2-inch plug included in the packaging.
NOTE: BODY, PLUG, AND ADAPTERS ARE
ABS PLASTIC - USE ABS TO PVC GLUE WHEN
PLUMBING TO PIPE.
CHECK FOR LEAKS BEFORE PROCEEDING
WITH THE INSTALLATION.
Follow the diagram to the right for proper
installation.
Take particular care when installing the float
lever. The entire assembly should be installed
by hand, and each adjustment should not
exceed ¼ of a turn.
Be sure unit is installed flush with the deck. To
adjust the water level loosen the wing nut, move
the float up or down, and tighten the nut.
25504-200-001- 2" Collar Extensions
(Sold Separately)
This product is must be installed and serviced by a pool and spa professional. These
instructions must be followed exactly to ensure proper function of the parts.
®
(ADAPTERS INCLUDED)
WARNING
!
WING NUT
FLOAT
25504-000-100
1", 1-1/2", OR 2"
SLIP CONNECTION
WHITE LID
25544-000-000
GRAY LID
25544-001-000
TAN LID
25344-019-000
VALVE
OVERFLOW
1/2" OR 3/4"
WATER INLET