3 Installation
3.1 Warning
Note: Do not dismantle; the fiber optics are fragile and any pinch or fold may damage them.
Hazards for the Operator
Active Laser receptacles emit radiation invisible to the naked eye. Never look directly
into or through the inside of an active receptacle without having previously ensured
that it is not connected to the power supply.
Caution: Although not considered overly dangerous for the eye, avoid accidental
exposure to the optic beam emitted from the fiber optic connectors.
3.2 Power Supply
The power supplies LKS-WSA and LKS-WSE, for 110V and 220V operation respectively, are
used to power the FEO-171p.
Each power supply provides a regulated +5 VDC / 750 mA power source.
The FEO-171p employs a mini XLR-3 Mini QG type (Switchcraft) connector for its power needs.
Figure here under provides a detailed pinout of the male connector.
Pin 1: Shield
Pin 2: GND
Pin 3: +5 VDC
Figure 3: Power supply connector pin out
3.3 4:2:2 video input
BNC type connector: Connect a 4:2:2 SDI signal,
3.4 Fiber Output
Single-mode 1310 nm SC/PC connector
Laser Transmitter for typical distances up to 10 km