Electrical
Model
HP
5FL-L
1/2
5FLJ
1/2
7FL, 7FLJ
3/4
Preparing to Start the Pump – Deep Well
Open control valve
as far as possible
and fill pump and
piping through
priming port
or priming tee.
2756 0197
Figure 9: Fill Pump
Replace all
fill plugs and
close control
valve completely.
2758 0197
Figure 10: Prime Pump
Table I: Wiring Chart – Recommended Wire and Fuse Sizes
Branch
Max
Fuse
Load
Rating
Amps
Amps
9.4/4.7
15/15
8.8/4.4
15/15
12.2/6.1
20/15
water inside pump, causing hazardous pressure in unit, risk of explosion
and possibly scalding persons handling pump.
pump to overheat, damaging seal and possibly causing burns to persons
handling pump. Fill pump with water before starting.
Step 1. Open the control valve as far as possible (see Figure 9). Then
Step 2. Deep Well: Replace all fill plugs; close the control valve
Step 3. Power on! Start the pump and watch the pressure gauge.
Step 4. After 2 or 3 minutes, the gauge should show pressure or you should
Distance in Feet (Meters);
0-100
101-200
(0-30)
(31-61)
14/14(2/2)
10/14(5.5/2)
14/14(2/2)
12/14(3/2)
12/14(3/2)
10/14(5.5/2)
Never run pump against closed discharge. To do so can boil
Never run pump dry. Running pump without water may cause
remove the priming plug from the pump and fill the pump, fill all
piping between the pump and the well, and make sure that all
piping in the well is full. If you installed a priming tee in the suc-
tion piping, remove the plug from the tee and fill the suction pip-
ing.
completely (Figure 10).
Shallow Well: Leave the control valve open (in a shallow well
installation, the control valve always stays open).
Deep Well: The pressure should build rapidly to 50 PSI as the
pump primes.
Shallow Well: The pump should pump water in two or three
minutes.
have water. If not, stop the pump, remove the fill plugs, reopen the
control valve, and refill the pump and piping. You may have to
repeat this two or three times in order to get all the trapped air out
of the piping. On a deep well, don't forget to close the control
valve each time before you start the pump.
Wire Size AWG (mm
2
)
201-300
301-400
(62-91)
(92-122)
10/14(5.5/2)
6/14(14/2)
10/14(5.5/2)
8/14(8.4/2)
8/14(8.4/2)
6/12(14/3)
6
401-500
(123-152)
6/12(14/3)
8/12(8.4/3)
6/12(14/3)