Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16
WARNING! This adjustment affects the safety level of the automatic system.
Check that the force applied to the road barrier beam complies with regulations in force.
Any change in speed requires a new calibration of the amperometric sensor.
A Faston (VMOT) connector is provided on the power supply transformer. This allows for the adjustment of
the road barrier motor speed at three different levels (18-23-26).
By positioning the Faston (VMOT) to 18 a lesser speed is provided, by moving the Faston to 26 a higher
speed is provided.
Should the VE.AM mobile stand or the VE.RAST rack be present, reduce the beam speed.
The control unit is provided with a series of self-diagnostic LEDs which permit to check all functions:
POWER LED
It flashes to indicate the presence of mains power supply
STOP LED
It switches off when the STOP button is activated
PhOT LED
It switches off when the photocells are not aligned or in the presence of obstacles
OPN LED
It switches on when the OPEN button is activated
CLS LED
It switches on when the CLOSE button is activated
PP LED
It switches on when the PP button is activated
SWC LED
It switches off when the SWC closing limit switch is activated
SWO-R LED
It switches off when the SWO-R opening braking limit switch is activated
SWC-R LED
It switches off when the SWC-R closing braking limit switch is activated
If the product must be dismantled, it must be disposed according to regulations in force regarding the
differentiated waste disposal and the recycling of components (metals, plastics, electric cables, etc..). For
this operation it is advisable to call your installer or a specialised company.
TO ADjUST ThE ROAD bARRIER SPEED
DIAGNOSTICS OF LEDS

WASTE DISPOSAL