INSTALLATION INSTRUCTIONS
C-AR-A-AL Series
DIRECT MOUNT ARM MOUNTING
(Requires use of C-AR-A-ALDM Accessory)
NOTE: Maximum tilt angle for the fixture is 30°. Fixture is not to be
used as an uplight.
1.
Use the template in Figure 9 on the last page, for pole drilling if
the pole is not predrilled.
NOTE: Template is not to scale.
2.
Remove side cover plate on arm by removing (4) screws holding
cover in place. Set screws and cover aside for later use. See
Figure 2 for square poles and Figure 3 for round poles.
3.
If backing plate is attached to arm, remove (2) 8mm bolts and
washers to free backing plate from arm.
4.
Position backing plate inside pole with large hole in plate aligned
with large hole in pole.
5.
Thread 8mm bolt, with lockwasher and flat washer in place,
through top holes in arm and pole and into top threaded hole in
backing plate. Do not fully tighten bolt at this time.
NOTE: Lockwasher must be positioned closest to bolt head.
NOTE: If mounting to a square pole, position radius cut gasket
between arm and pole. See Figure 2. Do not use gasket if
mounting to a 5" to 6" diameter round pole. See Figure 3.
6.
Repeat STEP 5 for second 8mm bolt through lower hole in arm,
gasket (if square pole), pole, and into lower hole in backing plate.
7.
Tighten both upper and lower bolts to 18 ft-lbs. (24.5 N•m).
8.
Pass (2) fixture cords through the slot in fixture side of arm and
into the inner chamber of the arm.
9.
While gently pulling cords through slot in arm, move fixture
towards arm, eventually aligning lower knuckle area with upper
knuckle area.
10. Partially tighten supplied 10 mm bolt with lockwasher and flat
washer on bolt to hold the two halves of fitter together. Make sure
the lockwasher is positioned closest to the head of the bolt. Do not
fully tighten bolt at this time.
11. Pass ends of cords through large hole in arm, gasket (if square
pole), pole, backing plate, and into pole.
12. Make wiring connections to cord leads inside pole per the
Electrical Connection section.
NOTE: Strain relief is required for electrical connections at
mounting heights of 25' (7.6m) and above. Knot the supply wires
from the pole with the fixture cords inside the pole to provide strain
relief.
13. Tilt the fixture to the desired angle and tighten the 10mm
adjustment bolt between the two halves of the knuckle to
32.5 ft-lbs. (44 N•m).
14. Carefully replace side cover on the arm using the (4) screws
removed in STEP 2. Be careful not to damage the arm gasket.
Tighten screws to 20 in-lbs. (2.5 N•m).
15. Replace pole cap.
TRUNNION MOUNTING
(Requires use of C-AR-A-ALTR Accessory)
NOTE: Maximum tilt angle for the fixture is 45°. Fixture is not to be
used as an uplight.
1.
Use keyholes slots in trunnion to mark mounting hole locations on
chosen mounting surface.
2.
Partially thread (2) 5/16" (8mm) fasteners appropriate for mounting
surface into mounting surface at locations marked in STEP 1.
3.
Feed fixture cords through slot in trunnion. See Figure 4.
http://lighting.cree.com/warranty
Document
LPN00851X0001A0_C
Created By:
TMT
4.
While gently pulling cords through slot in trunnion, move the
trunnion towards the fixture, eventually aligning the lower knuckle
area with the upper knuckle area. See Figure 5 on the next page.
5.
Partially tighten supplied 10 mm bolt with lockwasher and flat
washer on bolt to hold the two halves of fitter together. Make sure
the lockwasher is positioned closest to the head of the bolt. Do not
fully tighten bolt at this time.
6.
Bring fixture to mounting surface and insert heads of 5/16 (8mm)
fasteners from STEP 2 through keyhole slots in trunnion.
7.
Tighten trunnion to mounting surface with (2) fasteners.
8.
Tilt the fixture to the desired angle and tighten the 10mm
adjustment bolt between the two halves of the knuckle to
32.5 ft-lbs. (44 N•m).
9.
Make wiring connections to cord leads inside water tight wiring
compartment (supplied by others) per the Electrical Connection
section.
FIGURE 2- Square Pole
Pole Cap
DM Arm
Bolt
Square Pole
Radius Cut Gasket
Backing Plate
FIGURE 3- Round Pole
Pole Cap
DM Arm
Bolt
Round Pole
Backing Plate
FIGURE 4
Fixture
|
866.924.3645
Date:
06-22-2022
30° MAX
Fixture
Cover
30° MAX
Fixture
Cover
Trunnion