11
12
13
14, 15
16,17
18, 19
1) Cut off power supply.
2) Manually release the door, move it at around half stroke and lock it again.
3) Reset power supply.
4) Send an opening control signal through the OPEN input.
5) The door leaves should open. If not, with stopped motor, it is sufficient to invert the move wires
of the motor (MOT/MOT) of the motor and the limit switches (SWO/SWC), if used.
6) Adjust Times and operating Logics.
TW
It allows the maximum duration of opening and closing.
It must be preset approx. 4s more with respect to the actual stroke time of the
system.
The adjustment ranges from 3s to 180s maximum.
TCA
It allows to adjust the automatic closure time.
The adjustment ranges from 3s to 180s maximum.
Dip-Switches
Function
DIP1
TORQUE
DIP2
TCA
DIP3
DAS/PHOT
DIP4
SWC MODE
CLOSE
Input, CLOSE key (N.C. contact)
COM
Common, all control inputs.
OPEN
Input, OPEN key (N.O. contact).
24Vac
Output, 24Vac/400mA max accessory power supply.
SCA
Contact free from voltage, not insulated for the connection
of open gate indicator lamp.
Open contact with closed door leaf. Flashing light during
the door leaf movement. With open door leaf, the contact
is closed.
Connection to radio receiver antenna insertable board and
Antenna
incorporated radio module
(SHIELD-screen/ANT-signal).
CHECKING CONNECTIONS:
TRIMMER FUNCTIONS
DIP-SWITCH FUNCTION
Description
To be used for the programming of the torque, as shown
hereunder. After presetting the parameters, move to OFF
again.
The automatic closure is enabled or disabled.
Off: disabled automatic closure.
On: enabled automatic closure.
The operating mode of input DAS/PHOT is selected:
Off: partial reversion (3s) at activation of safety edge.
On: total reversion at activation of edge/photocell.
Off: during closure, if SWC is pressed, the motor is
blocked.
On: during closure, if SWC is pressed, the motor continues
its closing movement for further 2 seconds or until the
SAFETY EDGE is activated.
9