LED Driver Installation
Best Practices Guide
EcoSystem
®
Driver Mounting
Mount driver flush against fixture to provide best heat transfer. Avoid mounting driver close to heat source such as fixture cover plate
or light source. Installer is responsible for ensuring that the driver calibration point does not exceed the maximum rated temperature.
Stud Mounting
(Uses 8 – 32 Threaded Stud)
Correct
Incorrect
Power Wiring
WARNING: Shock hazard. May result in serious
injury or death. Disconnect power before servicing or
installing.
LDE Models
K Enclosure
1
GND
NEU
Power Input
(Line Voltage)
N/C
L
EcoSystem
®
E2
Digital Link
(Class 1 or
E1
Class 2)
2,3
1
Fixture must be grounded in accordance with local and national electrical
codes. Not all enclosures include ground terminal.
2
Class 2 must be separated from Class 1 and line voltage wiring by the
following: 0.25 in (6 mm) or physical barrier. Please refer to Application Note
#142 for further information.
3
EcoSystem
Digital Link length is limited by the wire gauge used for E1 and
®
E2 as follows.
EcoSystem
Digital Link Wiring
®
Digital Link
Wire Gauge
Length (max)
18 AWG
550 ft
16 AWG
900 ft
14 AWG
1400 ft
12 AWG
2200 ft
Digital Link
Wire Size
Length (max)
2
0.75 mm
155 m
1.0 mm
2
207 m
2
1.5 mm
310 m
2
2.5 mm
517 m
4.0 mm
2
828 m
To EcoSystem
Digital Link
®
compatible devices (up to 64)
Lutron Technical Support Hotline
Lutron, ), and EcoSystem are registered trademarks of Lutron Electronics Co., Inc.
NEC is a registered trademark of the National Fire Protection Association,
Quincy, Massachusetts.
UL is a registered trademark of Underwriters Laboratories, Inc.
www.lutron.com
5-Series
K Enclosures
Driver must be electrically grounded for proper performance and to meet UL
requirements. When using enclosure mounting tabs, grounding should be accomplished by using
paint-piercing mounting hardware to ensure electrical connection through driver enclosure and fixture.
M Enclosure
NEU
Power Input
N/C
(Line Voltage)
L
EcoSystem
®
E2
Digital Link
(Class 1 or
E1
Class 2)
2,3
1.800.523.9466
P/N 041456a
04/2014
Tab Mounting
M Enclosure
Driver Wiring
Wire Strip Length
For power, output, and digital terminals (E1, E2).
For proper wiring
Follow wiring schematic on driver being installed. Driver photos
are for reference only.
EcoSystem
5-Series, K Enclosure
®
3.00 in (76 mm) W × 1.00 in (25 mm) H × 4.90 in (124 mm) L
EcoSystem
5-Series, M Enclosure
®
1.18 in (30 mm) W × 1.00 in (25 mm) H × 14.25 in (362 mm) L
N
N/C
Load Wiring
L
Note: Class 2 output designed to withstand hot swap.
E2
E1
Driver
terminals
−V
N
+V
N/C
L
E2
E1
Wire Gauge
18 AWG (0.75 mm
16 AWG (1.5 mm
14 AWG (2.5 mm
12 AWG (4.0 mm
and NEC
®
Solid copper 18 –16 AWG
(0.75 –1.5 mm
5/16 in (8.0 mm)
See table below
Maximum Lead Length
200 mA –700 mA 710 mA –1.5 A 1.51 A –2.10 A
2
) 30 ft (9 m)
15 ft (4.5 m)
2
)
35 ft (10.5 m)
25 ft (7.5 m)
2
)
50 ft (15 m)
40 ft (12 m)
2
)
100 ft (30 m)
60 ft (18 m)
®
2
) wire
–V (Black)
LED
light
source
+V (Red)
10 ft (3 m)
15 ft (4.5 m)
25 ft (7.5 m)
40 ft (12 m)

Publicité

loading

Sommaire des Matières pour Lutron EcoSystem 5-Series

  • Page 1 18 AWG (0.75 mm ) 30 ft (9 m) 15 ft (4.5 m) 10 ft (3 m) Lutron, ), and EcoSystem are registered trademarks of Lutron Electronics Co., Inc. 16 AWG (1.5 mm 35 ft (10.5 m) 25 ft (7.5 m) 15 ft (4.5 m)
  • Page 2 0,75 mm (18 AWG) 9 m (30 pi) 4,5 m (15 pi) 3 m (10 pi) Lutron, ), et EcoSystem sont des marques déposées de Lutron Electronics Co., Inc. 1,5 mm (16 AWG) 10,5 m (35 pi) 7,5 m (25 pi) 4,5 m (15 pi) NEC est une marque déposée de la National Fire Protection Association de Quincy,...