H-8041
COMPACT AUTO
FLOOR SCRUBBER
OPERATING ISSUE
The machine does not work.
The brush does not rotate.
The machine does not
clean evenly.
Reduced power or speed.
PAGE 1 OF 9
1-800-295-5510
uline.com
TROUBLESHOOTING
CAUSES
The batteries need to be charged.
The brush button LED is off.
The brush motor thermal cutout has
tripped; the motor has overheated.
The batteries need to be charged.
The brush motor fuse has blown.
The brush or floor cleaning pad is
worn.
Unit may be in ECO mode.
• This mode runs unit at 80% power
resulting in reduced noise for use
in noise-sensitive environments.
• Indicator light for the motor
(brush motor or fan motor) will
show a slow blink.
Para Español, vea páginas 4-6.
Pour le français, consulter les pages 7-9.
RECOMMENDATIONS
Charge the batteries.
(See Instructions)
Press the brush button.
Turn the unit off. Let the machine
cool down for at least 45 minutes.
Charge the batteries.
Replace the brush motor fuse.
Replace the worn brush or floor
cleaning pad.
Turn off ECO mode.
• Hold button for applicable motor
(brush or fan) for 10-15 seconds
until light turns solid.
0122 TH-8041