INSTALL THE ROUGH-IN PLATE
. Run 0" round steel ductwork, from exterior ventilator to
the installation location. For best performance, use the
straightest possible duct run and the fewest number of
elbows. Tape all joints.
2. Run 20 VAC electrical power cable from service panel
and from remote ventilator to installation location.
3. Remove wiring box cover. Remove knockouts from the
wiring box. Feed 6" of power cable through openings
and attach cables to wiring box with appropriate connec-
tors.
GREEN / YELLOW
b
BLUE
BROWN
M
GROUND
b
BLACK
BLUE
WHITE
b
BLACK
BLUE
BLACK
CAPACITOR
EXTERIOR
BLACK
BLOWER
WHITE
ROUGH-IN PLATE LEAD
4. Wire black to black, white to white, and green or bare
wire beneath green ground screw. Replace wiring box
cover.
5. Connect ductwork to transition and tape joint.
6. Turn on power and check ventilator operation.
VIKING RANGE
gREENWOOD, mISSISSIPPI 38930 USA
WIRING BOX
GREEN
LINE IN
WHITE
120 VAC
BLACK
60 HZ
10 A MAX.
BLACK
WHITE
GREEN
ROUGH-IN PLATE LEAD
USE AND CARE
Disconnect electrical power supply and lock out service
panel before cleaning or servicing this unit.
CLEANING
Remove cover and carefully vacuum ventilator and inside
of housing. Be careful not to bend or otherwise damage
ventilator wheel.

MOTOR LUBRICATION

The motor is permanently lubricated. Do not oil or disas-
semble motor.