System Control Panel - Rheem GEN12S Manuel De L'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

System Control Panel

Compare this Control Panel illustration with your generator to familiarize yourself with the location of these important controls:
15 Amp Fuse
System Switch
Manual Over-Ride
Switch
Set Exercise
Switch
15 Amp Fuse — Protects the Home Generator System DC
control circuits. If the fuse has 'blown' (melted open) or was
removed, the engine cannot crank or start. Replace the fuse
using only an identical ATO 15A fuse.
Circuit Breaker — Protects the system from shorts and
other over-current conditions. Must be ON to supply power
to the Automatic Transfer Switch.
Digital Display — Displays the total number of hours the
generator has been running and fault codes. Used to
schedule maintenance tasks and troubleshooting operational
problems with the Home Generator System. All fault
conditions are described in the section "Fault Detection
System".
Manual Over-Ride Switch — With system switch in AUTO
position, push the manual over-ride switch to start the
generator. To turn off the generator, push and hold the
manual over-ride switch again until engine stops.
All manuals and user guides at all-guides.com
Service Tool
Service Tool — For use by qualified service personnel ONLY.
Set Exercise Switch — Used to set the exercise cycle start
time and day-of-the-week. Exercise cycle only occurs in
AUTO mode.
System Switch — This two-position switch is the most
important control on the system and is used as follows:
Digital Display
• "AUTO" position is the normal operating position. If a
utility power outage is sensed, the system will start the
generator. When utility power is restored, it lets the
engine stabilize internal temperatures, shuts off the
generator, and waits for the next utility power outage.
• "OFF" position turns off running generator, prevents
unit from starting and resets any detected faults.
Circuit
Breaker
11

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Gen15sGen20bGen25b

Table des Matières