ELECTRICAL SCHEME
Connector M12 female 5 contacts
INPUT / OUTPUT
2.bis. If Strobe Mode is selected, plug external trigger
(EXT TRIGGER)
(!!! Value depends on the lighting product)
2. Choose
Strobe Mode
or
Continuous Mode
1. M12 or M12 Power connector
(LED lighting connector)
The working is different according to the product. Some examples are given below :
EFFI-FLEX
(with trigger)
CONTINUOUS
If V
potentiometer
MODE
→ EFFI-FLEX is OFF
If 5V < V
→ EFFI-FLEX is ON
STROBE MODE
The voltage of external trigger
must be >5V to switch ON the
EFFI-FLEX
The potentiometer doesn't work
Power Supply
EFFI-BL
(with dimming control)
= 0V (min)
If V
→ EFFI-BL is OFF
< 24V (max)
If 5V < V
potentiometer
→ 20% < Luminous intensity of EFFI-
BL < 100%
The voltage of external trigger
allows to switch ON/OFF & sets the
Luminous intensity of EFFI-BL
The potentiometer doesn't work
Mini Parc du Verger – Bâtiment E
1 Rue de Terre Neuve
91940 LES ULIS, FRANCE
Connector M12 Power female 4 contacts
3.
In Continuous Mode: Set the DIM voltage between 0V and 24V
Or
in Strobe Mode: Set AIC voltage between 0V and 24V
= 0V (min)
potentiometer
< 24V
potentiometer
Tel: +33 9 72 38 17 80
UK Importer: Gardasoft Vision Ltd.
Fax: +33 9 72 11 21 69
Trinity Court, Buckingway Business Park
Email: sales@effilux.fr
Swavesey, Cambrige CB24 4UQ UK
USER MANUAL EFFI-PWR
Version 2.2.2022
Last update: February 23, 2022
EFFI-LASE-PSV
(with trigger & dimming control)
If V
= 0V (min)
potentiometer
→ EFFI-LASE-PSV is OFF
If 5V < V
< [10V ; 24V]
potentiometer
→ 20% < Luminous intensity of EFFI-BL <
100%
The voltage of external trigger allows to
switch ON/OFF the EFFI-LASE-PSV
The potentiometer sets Luminous
intensity of EFFI-LASE-PSV
Page 3 / 4