Item
4.4

Installation Conditions

• Cover the working area with a conductive or antistatic mat.
• No extreme changes in temperature that can cause condensation
• Free from dust, salts, or iron dust
• Not subject to water, oil, or chemicals
• No vibration and/or shock directly transmitted to the product
Observe the instructions in the manuals below when mounting the SERVOPACK with the safety
module already installed.
Name
Sigma-7-Series AC Servo Drive Linear/Rotary Servomotor with
400 V-Input Power, Product Manual
Sigma-7-Series AC Servo Drive Sigma-7S SERVOPACK with
400 V-Input Power and EtherCAT
Product Manual
Advanced Safety Module for Sigma-7 SERVOPACKs
SGD7S-
DA0 8
Be sure to always use the most recent version of this manual.
Before you install the SERVOPACK (e.g. in a control panel), please ensure that the serial
number of the product is recorded.
Installation conditions according to EMC directive
For installation conditions according to the EMC directive, please refer to the product manual
(manual number SIEP YEUOS7S 01, see above).
YASKAWA EUROPE TOMP YEUOS7S 01A – Sigma-7 Series Advanced Safety Module – Instruction Manual
Description
Safety I/O connector
Contact your Yaskawa representative for
more information.
Order No. JUSP-7CN21
Screwdriver
Wire cutters
(CoE) Communications
®
F91, 400 V, Product Manual
Manual number
SIEP S800001 81/86
SIEP S800002 30
SIEP YEUOS7S 01