Page 1
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
@XS-SLIM/HYBRID Table des matières Table Of Contents DESCRIPTION OVERVIEW .......................4 1.1. PRÉSENTATION DU PRODUIT PRODUCT PRESENTATION ..................4 1.2. CARACTÉRISTIQUES TECHNIQUES TECHNICAL CHARACTERISTICS ................. 5 1.3. ACCESSOIRES FOURNIS PROVIDED ACCESSORIES ..................5 OPÉRATIONS PRÉLIMINAIRES PRELIMINARY OPERATIONS ................6 2.1. FIXATION DE LA PLATINE PLATE INSTALLATION ....................
Page 3
@XS-SLIM/HYBRID 6.3. PAS DE CONNECTIQUE CUIVRE NO COPPER CONNECTION ................... 14 FINALISATION DE L’INSTALLATION FINALIZING THE INSTALLATION ..............15 RACCORDEMENT DU CLIENT CONNECTING THE SUBSCRIBER ..............15 MAINTENANCE MAINTENANCE ....................16 9.1. DISSOCIATION DE LA PRISE ET DE LA PLATINE SEPARATING THE OUTLET FROM THE PLATE ............16 9.2.
@XS-SLIM/HYBRID DESCRIPTION OVERVIEW 1.1. Présentation du produit Product presentation capot de protection, Protective cover cache pivotant, Swivelling flap corps comportant : Body including: support pour épissure fusion, Holder for fusion splice zone de lovage, Coiling area un raccord SC-APC autoprotégé One self-protected SC-APC adap- et un pigtail, ter and one pigtail...
@XS-SLIM/HYBRID OPÉRATIONS PRÉLIMINAIRES PRELIMINARY OPERATIONS 2.1. Fixation de la platine Plate installation Orientation de la platine. Plate orientation. La flèche indique le haut The arrow shows the upper de la prise. side of the outlet. 2.1.1. Par collage 2.1.2. Par vissage au mur Using tape Wall mounting with screws Ruban adhésif double face...
@XS-SLIM/HYBRID INSTALLATION DU CÂBLE CABLE INSTALLATION 4.1. Préparation du câble Cable preparation Câble simple gaine Single sheath cable 60 cm Gaine Module Sheath Module Câble double gaine Dual sheath cable L selon installation L according to configuration 60 cm Gaine extérieure Porteur Gaine intérieure Filin de...
@XS-SLIM/HYBRID 4.2. Mise en place du câble Cable installation ≤25 mm p. 11 (le cas échéant) Tube amorce (if required) Primer tube p. 12 ABS1440/A 10/20...
Page 11
@XS-SLIM/HYBRID ≤25 mm Choisir la sortie A, B, C ou D. Choose output A, B, C or D. p. 12 ABS1440/A 11/20...
@XS-SLIM/HYBRID MISE EN PLACE DE LA CONNECTIQUE CUIVRE (VERSION HYBRID) INSTALLING THE COPPER CONNECTION NETWORK (HYBRID VERSION) 6.1. Connectique coaxiale Coaxial connection 10mm Insérer d’abord la languette inférieure Insert the lower tab first Insérer le clip Insert the supérieur upper clip ABS1440/A 13/20...
@XS-SLIM/HYBRID 6.2. Connectique RJ45 RJ45 connection Insérer d’abord la languette inférieure Insert the lower tab first Connecteur RJ45 Insérer le clip Insert the non fourni. supérieur upper clip The RJ45 adapter is not provided. 6.3. Pas de connectique cuivre No copper connection Si besoin, installer l’obturateur à...
@XS-SLIM/HYBRID FINALISATION DE L’INSTALLATION FINALIZING THE INSTALLATION Étiquettes de repérage du logement Dwelling identification labels RACCORDEMENT DU CLIENT CONNECTING THE SUBSCRIBER Le pictogramme indique l’orientation pictogram indicates the correct correcte du détrompeur. orientation of the polarising slot. Détrompeur vers le haut Polarising slot directed upwards ABS1440/A 15/20...
@XS-SLIM/HYBRID MAINTENANCE MAINTENANCE 9.1. Dissociation de la prise et de la platine Separating the outlet from the plate 9.2. Dissociation de la platine et du rail DIN 9.3. Dissociation de l’adaptateur DIN et de Separating the plate from the DIN rail la platine Separating the DIN adapter from the plate...
@XS-SLIM/HYBRID 9.5. Remplacement d’un raccord Replacing an adapter Bouchon Plug Raccord SC : SC : Raccord SC en sachet : SC en sachet : ABS1440/A 19/20...
Page 20
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.