Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

1
ROUGH-IN REQUIREMENTS (see figure 2)
1. Check all items have been received.
1.
Towel Warmer
2.
Hardwire Kit (plate and tube)
3.
Bracket Pack (4 brackets)
2. Your towel warmer requires 110V GFCI protected power. The power feed should be located in a
single gang electrical box as shown in figure 2. Please ensure correct location of the electrical box on
the bottom right, as this will govern your towel warmer location. Do not install towel warmer upside
down.
3. Wall studs or plywood backing is recommended in the wall at all bracket
locations. See figure 2 for bracket locations.
2
INSTALLATION INSTRUCTIONS (see figure 1)
1. Fix wall supports "A" to the wall using the screws provided and in
locations as shown on figure 2.
2. Hang and adjust the towel warmer using set screws "B" to lock stud "C" in
the wall bracket "A". Ensure the towel warmer is firmly and safely fixed.
3
HARDWIRE CONNECTION (see figure 4)
TURN OFF POWER SUPPLY BEFORE PROCEEDING
Do not connect the towel warmer to the power supply until all instructions have been read and
installation carried out in accord with them. Your towel warmer is 150W (110V) and conforms
to CSA standards (File ref: 2422531). Please ensure the CSA label is visible.
1. Feed the electrical cord located at the bottom of the towel warmer first through the round tube then
through the cover plate.
2. Complete all electrical connections as shown in figure 3.
3. Push cover plate onto tube and screw to electric box with the enclosed screws. Adjust where necessary
- see figure 4.
Warning: In case of damage or failure of the towel warmer the unit should be returned to the manufacturer or their distributor. The
warranty of 2 years on the towel warmer is NOT VALID in case of improper use or installation. Product is designed for use within Canada
and the United States only.
Kontour Square Towel Warmer Installation Guide
Code: K6033W / K6034W / K6035W
24" x 40" Hardwire
FIGURE 1
877 757 8930
cs@icobath.com | www.icobath.com

Publicité

loading

Sommaire des Matières pour Kontour K6033W

  • Page 1 Kontour Square Towel Warmer Installation Guide Code: K6033W / K6034W / K6035W 24” x 40” Hardwire ROUGH-IN REQUIREMENTS (see figure 2) 1. Check all items have been received. Towel Warmer Hardwire Kit (plate and tube) Bracket Pack (4 brackets) 2. Your towel warmer requires 110V GFCI protected power. The power feed should be located in a single gang electrical box as shown in figure 2.
  • Page 2 Kontour Square Towel Warmer Installation Guide Specifications & Code: K6033W / K6034W / K6035W Drawings 24” x 40” Hardwire Model # Description Finish Weight Watts Volts Metal (lb) (mm) (Inches) Type Stainless K6033W Square Electric Hardwire Chrome 150W 110V 610 x 1015...
  • Page 3 Guide d’installation du sèche-serviettes Kontour Square Code: K6033W / K6034W / K6035W Console murale 24 po x 40 po REQUIS POUR L’INSTALLATION (voir la figure 2) 1. Vérifier qu’il ne manque aucune pièce. Sèche-serviettes Structure d’alimentation (plaque électrique et tube) Ensemble de 4 montants de fixation murale 2.
  • Page 4 Guide d’installation du sèche-serviettes Kontour Square Spécifications et Code: K6033W / K6034W / K6035W Schémas Console murale 24 po x 40 po No de Description Finition Poids Watts Volts Type de modèle (lb) (mm) (pouces) métal Éléments d’alimentation Acier électrique...

Ce manuel est également adapté pour:

K6034wK6035w