Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

KPA-1000

4. Specifications

Function
Range
60.00A
AC True RMS Current
600.0A
(Auto-ranging)
2000A
Over rang protection: Maximum input 2000A
Accuracy specified from 5% to 100% of the measuring range
Frequency Response: 50Hz to 60Hz True RMS
Function
Range
60.00A
DC Current
600.0A
(Auto-ranging)
2000A
Over rang protection: Maximum input 2000A
Function
Range
600.0mV
6.000V
DC Voltage
60.00V
(Auto-ranging)
600.0V
1000V
Maximum Input:1000V dc
Function
Range
6.000V
AC True RMS Voltage
60.00V
(Auto-ranging)
600.0V
1000V
AC Response: 50 Hz to 1kHz
Accuracy specified from 5% to 100% of the measuring range
Accuracy PEAK function: ±10%rdg
Maximum Input: 1000V ac rms.
5
EN
Accuracy
Resolution
(% of reading + digits)
10 mA
±2.5% of rdg + 8 digits
100mA
±2.5% of rdg + 8 digits
1A
±2.8% of rdg + 8 digits
Accuracy
Resolution
(% of reading + digits)
10 mA
±2.5% of rdg + 8 digits
100mA
±2.5% of rdg + 8 digits
1A
±2.8% of rdg + 8 digits
Accuracy
Resolution
(% of reading + digits)
0.1mV
±0.9% of rdg + 5digits
1mV
±1.0% of rdg + 3digits
10mV
±1.0% of rdg + 3digits
100mV
±1.0% of rdg + 3digits
1V
±1.0% of rdg + 3digits
Accuracy
Resolution
(% of reading + digits)
1mV
±1.2% of rdg + 5digits
10mV
±1.2% of rdg + 5digits
100mV
±1.5% of rdg + 5digits
1V
±1.5% of rdg + 5digits
EN
Function
Range
Resolution
600.0Ω
0.1Ω
6.000kΩ
Resistance
60.00kΩ
10Ω
(Auto-ranging)
600.0kΩ
100Ω
6.000MΩ
1kΩ
60.00MΩ
10kΩ
Input Protection: 600V dc or 600V ac rms.
Function
Range
Resolution
60.00nF
10pF
600.0nF
0.1nF
Capacitance
6.000uF
1nF
(Auto-ranging)
60.00uF
10nF
600.0uF
0.1uF
6000uF
1uF
Input Protection: 600V dc or 600V ac rms.
Accuracy is not stated below 6nF
Frequency with test leads(AC Voltage)
Function
Range
Frequency (Auto-ranging)
10Hz to 20kHz
Input Protection: 1000V AC rms
Sensitivity: >15V AC rms
Frequency with clamp (AC current)
Function
Range
Frequency (Auto-ranging)
40Hz to 1kHz
Maximum Input: 1000A AC
Sensitivity: >50A (600A range)
>500A (2000A range)
KPA-1000
Accuracy
(% of reading + digits)
±1% of rdg + 4digits
±1.5% of rdg + 2digits
±1.5% of rdg + 2digits
±1.5% of rdg + 2digits
±2.0% of rdg + 5digits
±3% of rdg + 8digits
Accuracy
(% of reading + digits)
±5% of rdg + 30digits
±3% of rdg + 5digits
±3% of rdg + 5digits
±3% of rdg + 5digits
±4% of rdg + 10digits
±4.5% of rdg + 10digits
Accuracy
(% of reading + digits)
±(1.0% +5 digits)
Accuracy
(% of reading + digits)
±(1.0% +5 digits)