Lutron Homeworks HWI-LV32-120 Instructions D'installation page 2

Publicité

Les langues disponibles

Les langues disponibles

D D a a n n g g e e r r - Ensure the processor feed breaker is OFF
when wiring or plugging in the Processor Assembly
Power Cord.
5 5 . . I I n n s s t t a a l l l l L L o o w w V V o o l l t t a a g g e e A A c c c c e e s s s s o o r r y y B B o o a a r r d d s s i i n n a a c c c c o o r r d d a a n n c c e e w w i i t t h h
i i n n s s t t r r u u c c t t i i o o n n s s p p r r o o v v i i d d e e d d w w i i t t h h t t h h e e b b o o a a r r d d s s . . Two configurations
are possible (not every board need be installed for a given
configuration):
a a . . D D i i m m m m e e r r I I n n t t e e r r f f a a c c e e / / H H u u b b C C o o n n f f i i g g u u r r a a t t i i o o n n - - Install one HWI-
D48 Dimmer Interface Board or HWI-H48 Dimmer Hub
and up to three HWI-WLB Wire Landing Boards as
shown in Figure 3. The upper left corner mounting hole
for the Dimmer Hub/Board is identified by a pink dot on
the rough-in enclosure. The upper left corner mounting
hole for the Wire Landing Boards are identified by green
dots on the rough-in enclosure. Connect ground wires
to the enclosure using any convenient holes.
b b . . C C o o n n t t a a c c t t C C l l o o s s u u r r e e B B o o a a r r d d / / H H W W I I - - Q Q 9 9 6 6 I I n n t t e e r r f f a a c c e e
C C o o n n f f i i g g u u r r a a t t i i o o n n - - Install up to two Contact Closure
Boards (HWI-CCO-8 or HWI-CCI-8) or HWI-Q96
Interfaces, and up to two HWI-WLB Wire Landing
Boards as shown in Figure 4. The upper left corner
mounting holes for the Contact Closure Boards/HWI-
Q96 Interfaces are identified by orange dots on the
rough-in enclosure. The upper left corner mounting
holes for the Wire Landing Boards are identified by the
green dots on the rough-in enclosure. Connect ground
wires to the enclosure using any convenient holes.
6 6 . . I I n n s s t t a a l l l l c c o o v v e e r r . . Ensure vents are on the right hand side of the
cover. Tighten screws to 20 in-lbs. (2.3 N
T T e e c c h h n n i i c c a a l l a a n n d d S S a a l l e e s s A A s s s s i i s s t t a a n n c c e e
If you need assistance, call the toll-free L L u u t t r r o o n n T T e e c c h h n n i i c c a a l l
S S u u p p p p o o r r t t C C e e n n t t e e r r . Please provide exact model number
when calling.
+1.800.523.9466 (U.S.A., Canada and the Caribbean)
Other countries call:
Tel:
+1.610.282.3800
Fax:
+1.610.282.3090
Visit our web site at www.lutron.com
Figure 4 - Contact Closure Board Configuration
Wire Landing Board
(NEC Class 2; IEC
m).
LIMITED WARRANTY
(Valid in the U.S., Canada, Puerto Rico, and the Caribbean)
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture
within two years after purchase. For warranty service, return unit to place of purchase or mail
to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre-paid. Telephone the
Lutron Technical Support Center toll free at 800-523-9466. After the two year period, a pro-
rated warranty applies to this product until eight years after the purchase. For more informa-
tion regarding this warranty contact your Lutron representative.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE
IMPLIED WARRANTY OF MERCHANTABILITY IS LIMITED TO TWO YEARS
FROM PURCHASE. THIS WARRANTY DOES NOT COVER THE COST OF INSTAL-
LATION, REMOVAL OR REINSTALLATION, OR DAMAGE RESULTING FROM MIS-
USE, ABUSE, OR IMPROPER OR INCORRECT REPAIR, OR DAMAGE FROM
IMPROPER WIRING OR INSTALLATION. THIS WARRANTY DOES NOT COVER
INCIDENTAL OR CONSEQUENTIAL DAMAGES. LUTRON'S LIABILITY ON ANY
CLAIM FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE MAN-
UFACTURE, SALE, INSTALLATION, DELIVERY, OR USE OF THE UNIT SHALL
NEVER EXCEED THE PURCHASE PRICE OF THE UNIT.
This warranty gives you specific legal rights, and you may also have other rights which vary
from state to state. Some states do not allow limitations on how long an implied warranty
lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or
limitation of incidental or consequential damages, so the above limitation or exclusion may not
apply to you.
Lutron and HomeWorks are registered trademarks of Lutron Electronics Co., Inc.
© 2005 Lutron Electronics Co., Inc.
Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299
Made and printed in the U.S.A. 10/05 P/N 043-127 Rev. B
HWI-WLB
PELV)
Cable tied but not
connected
HomeWorks Wired
Processor
Two HWI Contact
Closure Boards:
HWI-CCO-8 and/or
HWI-CCI-8
(NEC Class 2; IEC
PELV)