TIME CLOCK & DOCUMENT STAMP
Model 3500/3700
REPLACING RIBBON CARTRIDGE
Unplug time clock *IMPORTANT*.
1
2
Unlock and remove cover.
3
Turn clock on its side so ribbon cartridge & holder are on top.
4
Manually slide ribbon cartridge carriage to far right (see diagram).
5
Remove old ribbon cartridge. Gently push the ribbon tab away from the
ribbon cartridge and remove the cartridge.
6
Snap in new cartridge while turning the ribbon advance knob. Make certain
the ribbon and the clear plastic protector slide completely over print head.
7
Replace cover, lock unit & plug in.
8
Test time card or document for print quality.
If ribbon is not completely over print head the resulting print will show incomplete
characters. If ribbon cartridge is not completely snapped in holder, the resulting print
will be increasingly lighter.
pyramidtimesystems.com
Ribbon advance
REPLACING RIBBON CARTRIDGE
Print head
Ribbon tab
knob
9